Loading...
HomeMy WebLinkAbout1938 Blue Yonder Way - Disclosures/Final Energy - 05/16/2017IECC 2012 Performance Compliance QnergyLogic Property Organization --• •• • •• .• •••-••• DR Horton EnergyLogic 1938 Blue Yonder Way 9705560711 Inspection Status Ft Collins, CO 80525 Neal Guard 5/16/17 Rater ID (RTIN): 4606190 Template - DR Horton - 1960 FB Plat Builder RESNET Confirmed 1938 Blue Yonder Way DR Horton V: DR Horton Annual Energy Cost Design IECC 2012 As Designed Heating Performance Cooling $739 $704 Water Heating S100 $169 $91 $169 SubTlotal - Used to determine compliance $1,009 $964 Lights & Appliances $883 $868 Onsite generation $0 $0 Total $1,892 $1,832 Performance -based compliance Air Leakage Testing Area -weighted average fenestration passes by 4 4% SHGC 2.2 Tar - Area -weighted average fenestration Duct Testing Lighting Equipment Efficiency Ll-Fedor Mandatory Checklist �� Mi Design exceeds requirements for IECC 2012 Performance compliance by 4.4%. Name Neal Girard Organization- EnergyLogic Signature Date May 16, 2017 Ekotrope HERS Rating Tool - Version 21.0.1693 IECC 2012 Pedormame compliance results calculated fining Ekarope s energy algorithm which Is a RESNET Amredted IECC Ra0ng Tool No Text Air Leakage Report QnergyLogic ProPe�Y Organization �•��n�. �.�ia�r •u�... DR Horton EnergyLogic 1938 Blue Yonder Way 9705560711 Inspection Status Ft Collins,CO 80525 Neal Girard 5H6/17 Rater ID(RTIN):4606190 Template-DR Harton- 1980 FB Plai Builder RESNET Confirmed 1938 Blue Yonder Way DR Horton V; DR Horton Air Leakage Measurement Unit CFM at 50 Pa ' Measured Infiltrahon 1550 ACH50(Calculated) 2 q ELA[sq. m.] (Calculated) 85.3 Duct Leakage Number of Duct Systems 1 System(s) Leakage to Outdoors[CFM @ 25 Pa] 0.0 Leakage to Outdoors[CFM25/100 s.f.] 0.0 Leakage to Outdoors[CFM25/CFA] 0.000 Total Leakage Test Type Post-Constructron Total Leakage[CFM @ 25 Pa] 96.0 Total Leakage[CFM25/ 100 s f] 2 4 Total Leakage(CFM25/CFA] 0 024 Mechanical Ventilation Rate[CFM] 79 0 Hours per day 24.0 Fan Watts 15.0 Recovery EffiGency 96 0.0 Runs at least once every 3 hrs? true Average Rate(CFM] 7g p 2010 ASHRAE 62.2 Req. Cont.Vent8a6on 69.5 EkoUope HERS Ratmg Tool-Version 2.1.0.1693 -- -- - -- --- - _._...--- - - -� -- - _.. - - - -- - - - -- ._...- ---- -. 1938 Blue Yonder Wa � Ft Collins, CO 80525 � � DR Horton � � � • � � • ' ' • ' ' • • 1 � i Building Features � Ceiling Flat R-38 Duct Supply R-0 0,Return R-0 0 ' Above Grade Walls R-21 Duct Leakage to Outside 0 0 CFM @ 25 Pa ' I Foundation Walls R-19 Total Duct Leakage 96 0 CFM @ 25 Pa i Framed Floor N/A Heating Fumace• Natural Gas• 92 1 AFUE ! Slab R-0.0 Penmeter, R-0 0 Under Cooling Air Conditioner•Electnc• 13 SEER ! Infiltration 1550 CFM50(2.4 ACH50) Water Heating Water Heater•Natural Gas•0 59 Energy Factor ' wndow U-Value 0 31 SHGC.0 40 The orgenization below certifles that the proposed building design described herein is consistent with the building plans, I specifications,and other calculadons submitted with the permtt applicatlon.The proposed buflding has been designed to meet the 2012 ' IECC requlrements In compllance with Chapter 4 based on Cltmate Zone 5 and wlth all mandato requlre nts. � Name Neal Girard Signature: 1 Organization EnergyLogic Date: May 16, 2017 Ekotrope HERS Raurg Tool-Version 21.0.1693 No versbn ol Ihb soflware has been revkwed or epproved by ICC or Ms aROates � The 2012 Intenatlonal Enagy ConservaWn Code is a regmerad trademark o1 the IntemaEmel Code Coimd,Inc ('ICC) �I Thb soRware has been acaedued by RESNET to demonsuate IECC Per(ortnaixa Path Complim�ce ! I Home Energy Rating Certificate Rating Date: 5/16/17 QnergyLogic Registry ID: 635059106 •••'•�'�• '••'•�� �••-••• Final Report Rating Number: 635059106 . o • - • � � � . . . - - - . .- . � '- ' - • ' • •- • • . . . . . • ' � - • ' • - - � • . . • - -•' • - Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu1 Annual Cost criteria of the following: Heating 67.7 $695 2012 International Energy Conservation Code Cooling �,� S� Hot Water 17.6 S156 Lights/Appliances 29.7 $967 Service Charges . 50 Generetion (e.g.Solar) 0.0 -$0 Total: 116.1 S1,857 �� Home Feature Summary: Rating Completed by: � ��o Home7ype Singlefamllydetached w CondrtionedFloorArea 3,952sq.h EnergyRater.NealGirard �� fO Number of eedrooms 3 RESNET ID:4606190 "o�. ,,, i� Primary HeaLng System Fumate•Natural Gas•92.1 AFUE Rating Company:Energylogic R��e = ua Pnmary Cooling System Air CondlUoner•Electric•13 SEER PO Box N Berthoud,CO 80513 Nm�e � � Primary Water Heating Water Heater•Natural Gas•0 59 Energy Factor �970)556-0839 90 HouseTtghtness 1550CfM50(2.4ACH50) RatingProvider.EnergyLogic e A Duct Leakage to Outside OCFM25 PO Box N Berthoud,CO 80513 .��.� AboveGradeWalls R-21 .. }� �� ' (970)556-0839 ��?�� � na�naw Ceiling R-38 � �. � � wndow7ype U-Value 0310,SHGC.0400 3 '���E 6 � Foundation Walls H-19 '�;;,�� � "°"'° ° Neal Girerd, Certified Energy Rater ��.�., � �� • • • ' . ..• .. . � .• . . . . � .. . . .. • . . . .• •.. .• . . . ..