HomeMy WebLinkAbout2133 S Timberline Rd - Disclosures/Blower Door Test - 11/10/2016QnergyLogic analysis. Insight. answers. BUILDING LEAKAGE TEST Date of Test: 11/10/2016 Test File: Customer: Elder Construction Technician: Peter Oberhammer Project Number: 43695 Building Address: Holmes Dental 2133 Timberline Ft Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 2445 CFM50 (50 Pa = 0.2 w.c.) 2.87 ACH50 t{ l 2. Leakage Area: 134.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 192.3 Exponent (n) = 0.650 (Assumed) 4. Test Settings: Test Standard: RESNET One -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 151.5 CFM 0.18 ACH 25.3 CFM per person 2. Estimated Design Infiltration Rate: Winter: 268.1 CFM Summer: 168.3 CFM 0.32 ACH 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: QnergyLogic � BUILDING LEAKAGE TEST Page 2 of 4 ` Date of Test: 11/10/2016 Test File: Building Information Location Climate Information Volume 51026 Ventilation Weather Factor 0.87 Surface Area 9755 Energy Climate Factor 17.00 FloorArea 2628 Heating Degree Days 6128 Height 24.5 Cooling Degree Days 297 #of Bedrooms 1 Design Winter Wind Speed 7.3 mph #of Occupants 6 Design Summer Wind Speed 9.4 mph I Year of Construction 2016 Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost . Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 42382 Default I ' Micromanometer Energy Conservatory DG700 � QnergyLogic � BUILDING LEAKAGE TEST Page 3 of 4 � Date of Test: 11/10/2016 Test File: Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude(ft) 70.0 40.0 5280.0 . Baseline Pressure Data ' Baseline 1 (Pa) .1 Baseline 2 .1 Baseline 3 .1 Baseline 4 .1 Baseline 5 .1 Average Baseline(Pa) 0.1 Baseline Range(Pa) 0.0 Data Points- Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) Configuration -50.0 . -50.1 26.4 2501 2448 Open Time Averaging Period: 30 Deviations from Standard RESNET One-Point Test-Test Parameters None QnergyLogic � BUILDING LEAKAGE TEST Page 4 of 4. - � da�e of Test: 11/10/2016 Test File: Comments Building passes 2012 IECC ACH requirement. Tested at 2.87 ACH. No garage so garage connection test not needed. �