Loading...
HomeMy WebLinkAbout6209 Swainsons Hawk Pl - Disclosures/Final Energy - 05/10/2016BEZ=�� BURGESS EI�IEFIGY SEFIVICI A DIVISION OF BURGESS CONSTRUCTION CONSULTANTS. INC. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: May 17, 2016 Rating No.: 012720160632YK Building Name: Costa Owner's Name: Toll Brothers Property: 6209 Swainsons Hawk Place Address: Fort Collins, CO 80528 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO File Name: 6209 Swainsons Hawk Place.blg Heating: Cooling: Water Heating: SubTotal - Used to Determine Compliance: Lights &Appliances: Photovoltaics: Service Charge: Total: Rating Org.: Burgess, Inc. - BCCI Phone No.: 303-300-4527 Rater's Name: Barrett Hendricks Rater's No.: 6761425 Rating Type: Confirmed Rating Date: 05/17/2016 2012 IECC -...._ 788 244 159 1191 1180 -0 240 2611 Annual Energy Cost ($) As Designed - 614 231 159 4nnA I I'Fy -0 240 2394 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.290 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 58. In fact, this home surpasses the requirements by 15.6%. Name: Barrett Hendricks Signature: Organization: Burgess, Inc. - BCCI Date: May 17, 2016 REM/Rate - Residential Energy Analysis and Rating Software v14.6.2.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Costa Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 56.0 kBtuh, 92.1 AFUE. Heating: Fuel -fired air distribution, 70.0 kBtuh, 80.0 AFUE. Cooling:Airconditioner, 18.0 kBtuh, 13.0 SEER. Cooling:Air conditioner, 30.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.68 EF. Window -to -Floor Area Ratio:0.12 Blower door test: Htg: 1585 Clg: 1585 CFM50 Page 2 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software 04.6.2.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. a � :. BURGESS Costa eniew�veewv�ces 6209 Swainsons Hawk Place ........ .... ..�� .........-..,.. Fort Collins, CO 80528 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 1 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 53 Efficient Home Comparison: 47% Better General Information Conditioned Area: 5828 sq. ft. HouseType: Single-family detached Conditioned Volume: 60216 cubic ft. Foundation: More than one type Bedrooms: 5 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Heating: Fuel -fired air distribution, Natural gas, 80.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Duct Leakage to Outside: 47.00 CFM25. Ventilation System: Exhaust Only:103 cfm, 11.3 watts. 11 Programmaoie i nermostat: Heabng: Yes uounng: Yes Building Shell Features _. . . ... ....... ..........---..._...__ Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-48.0 Vaulted Ceiling: NA Window Type: U-Value: 0.290, SHGC: 0.330 Above Grade Walls: R-21.0 Infiltration Rate: Htg:1585 Clg: 1585 CFM50 Foundation Walls: R-19.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 475.00 Clothes Dryer EF: 2.67 Dishwasher (kWh/yr): 260.00 Ceiling Fan (cfm/Watt): 0.00 Registry ID: 577684404 Rating Number: 012720160632YK Certified Energy Rater: Barrett Hendricks Rating Date: 05/17/2016 Rating Ordered For: Toll Brothers Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 89.3 $587 26% Cooling 4.3 $126 6% Hot Water 26.7 $160 7% Lights/Appliances 39.2 $1149 51 % Photovoltaics -0.0 $-0 -0% Service Charges $240 11 % Total 159.6 $2262 100% This home meets or exceeds the minimum criteria for all of the following: 2006 International Energy Conservation Code 2009 International Energy Conservation Code 2012 International Energy Conservation Code �j r0oRTGAG � , , BurgessConstructionConsultantsl 101 W Renner Rd, Suite 400 Ze - saw Richardson; Texas 75082 riCA m 214-888-7260 No. 1998-744/ AAt The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 214-888-7261 �s G REM/Rate - Residential Energy Analysis and Rating Software v14.6.2.1 �� `� �CCRE°�TAT�: This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. Certified Energy Rater