HomeMy WebLinkAbout5720 Big Canyon Dr - Disclosures/Blower Door Test - 10/19/2016BUILDING LEAKAGE TEST
nergy..o
anol.ysis... insight. ensurers:...
rnr Io scorn
g
Date of Test: 10/19/2016
Customer: Ryland Homes
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Test File: Multi Point Tectite 5720
Technician: Trevor Donnelly- EnergyLogic
Project Number: 43302
Building Address: 5720 Big Canyon dr
Ft Collins, CO 80528
1608 CFM50 (+/- 3.1 %)
2.46 ACH50
88.4 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 40.1 (+/- 51.9 %)
Exponent (n) = 0.944 ( +/- 0.136 )
Correlation Coefficient = 0.98969
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate: Winter: 176.4 CFM Summer: 110.7 CFM
0.27 ACH 0.17 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
QnexgyLogid
w;vM,14091C.Com.. BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720
Building Information
Volume
39178
Surface Area
Floor Area
Height
, 20
# of Bedrooms
3
#of Occupants _
4 _
Year of Construction
2016
Wind Shield
M
Heating and Cooling Cost and" Efficiency Information
Heating Fuel
Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
_
Cooling SEER
Location Climate Information
j Ventilation Weather Factor
0.87 -�
Energy Climate Factor
17.00 J
Heating Degree Days
Cooling Degree Days
Design Winter Wind Speed
6128
_ _297
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff �_
15 deg F j
Equipment Information
Type Manufacturer Model I Serial Number I Custom Calibration Date
Fan Energy Conservatory Model 3 (110V) _ Default
QnergyLogic
yvwwniglogic.com:. BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720
Depressurization Test:
Environmental Data
Indoor Temperature (OF)
Outdoor Temperature (OF)
Altitude (ft)
70.0
i 50.0
5000.0
Data Points
Nominal Baseline Adjusted Fan
Building Pressure Building Pressure Pressure
(Pa) (Pa) (Pa) -
Nominal Adjusted
Flow Flow Fan
(cfm) (cfm) % Error Configuration
-3.5
n/a
n/a
-61.0
-57.3
95.9 1759 1797
-1.7
Ring A
-60.0
-56.3
90.3 1708 1746
-2.9
Ring A
-54.1
-50.3
78.4 1595 1630
0.7
Ring A
-51.0
-47.2
71.7 1527 1560
2.5
Ring A
-48.2
-44.4
65.2 1458 1490
3.6
Ring A
-44.0
-40.2
53.3 1320 1349
3.1
Ring A
-39.6
-35.8
36.9 1104 1128
-4.0
Ring A
-35.7
-31.9
31.4 1021 1043
-1.0
Ring A
-4.0
n/a
n/a
Time Averaging Period: 0
Deviations from Standard RESNET Multi -Point Test - Test Parameters
None
- * correlation coefficient outside of normally accepted limits.
* n value and/or correlation
coefficient limits are not officially part of
the RESNET
Multi -Point Test
Standard.
Qne:xgyLogic
yyUnv,niglogic:com BUILDING LEAKAGE TEST Page 4 of 4
:.
Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720
Comments
Connection to:
Garage: -45 Pa
Mechanicals: -50 Pa