Loading...
HomeMy WebLinkAbout5720 Big Canyon Dr - Disclosures/Blower Door Test - 10/19/2016BUILDING LEAKAGE TEST nergy..o anol.ysis... insight. ensurers:... rnr Io scorn g Date of Test: 10/19/2016 Customer: Ryland Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Test File: Multi Point Tectite 5720 Technician: Trevor Donnelly- EnergyLogic Project Number: 43302 Building Address: 5720 Big Canyon dr Ft Collins, CO 80528 1608 CFM50 (+/- 3.1 %) 2.46 ACH50 88.4 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 40.1 (+/- 51.9 %) Exponent (n) = 0.944 ( +/- 0.136 ) Correlation Coefficient = 0.98969 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Winter: 176.4 CFM Summer: 110.7 CFM 0.27 ACH 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: QnexgyLogid w;vM,14091C.Com.. BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720 Building Information Volume 39178 Surface Area Floor Area Height , 20 # of Bedrooms 3 #of Occupants _ 4 _ Year of Construction 2016 Wind Shield M Heating and Cooling Cost and" Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost _ Cooling SEER Location Climate Information j Ventilation Weather Factor 0.87 -� Energy Climate Factor 17.00 J Heating Degree Days Cooling Degree Days Design Winter Wind Speed 6128 _ _297 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff �_ 15 deg F j Equipment Information Type Manufacturer Model I Serial Number I Custom Calibration Date Fan Energy Conservatory Model 3 (110V) _ Default QnergyLogic yvwwniglogic.com:. BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 70.0 i 50.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) - Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration -3.5 n/a n/a -61.0 -57.3 95.9 1759 1797 -1.7 Ring A -60.0 -56.3 90.3 1708 1746 -2.9 Ring A -54.1 -50.3 78.4 1595 1630 0.7 Ring A -51.0 -47.2 71.7 1527 1560 2.5 Ring A -48.2 -44.4 65.2 1458 1490 3.6 Ring A -44.0 -40.2 53.3 1320 1349 3.1 Ring A -39.6 -35.8 36.9 1104 1128 -4.0 Ring A -35.7 -31.9 31.4 1021 1043 -1.0 Ring A -4.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. Qne:xgyLogic yyUnv,niglogic:com BUILDING LEAKAGE TEST Page 4 of 4 :. Date of Test: 10/19/2016 Test File: Multi Point Tectite 5720 Comments Connection to: Garage: -45 Pa Mechanicals: -50 Pa