HomeMy WebLinkAbout6744 Snowdon Dr - Disclosures/Blower Door Test - 08/18/2016® Build
Home Services
Date of Test: 8/18/2016
Customer: Insignia Homes
Dan Moore
550 N Lincoln Ave
Loveland, CO 80537
Phone: 970-379-7696
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5.' Accuracy Level
BUILDING LEAKAGE TEST
TopBuild Home Services
Environments For Living
260 Jimmy Ann Drive
Daytona Beach, FL 32114
mail: Colleen.Locker@TopBuild.com Website: www.environmentsforliving.cor
Test File: 6744 Snowdon Dr - Magnolia - Techtite
Technician: Colleen Locker
Project Number:
Building Address: Magnolia
6744 Snowdon Dr
Fort Collins, CO 80526
1188 CFM50 (+/-1.9 %)
1.65 ACH50
65.3 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 73.2 ( +/- 14.4 %)
Exponent (n) = 0.712 ( +/- 0.040 )
Correlation Coefficient = 0.99846
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
' Home Services
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 8/18/2016 Test File: 6744 Snowdon Dr - Magnolia - Techtite
Building Information
Volume _
_ 43098 —
_
Surface Area
Floor Area
4057
Height
I # of Bedrooms
# of Occupants
j Year of Construction
2016
Wind Shield- —
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel
Gas
Heating Fuel Cost__—
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
—
Type
Fan ---- --
Micromanometer
Location Climate Information
Ventilation Weather Factor
Energy Climate Factor
0.87
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
Design Summer Wind Speed
_ _ 7.3 mph —�
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Manufacturer I Model
Energy Conservatory Model 3 (110V)
Energy Conservatory DG700
Serial Number I Custom Calibration
9876 -
24427-7 I 1 /17/2013
Home Services
BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 8/18/2016 Test File: 6744 Snowdon Dr - Magnolia - Techtite
Depressurization Test:
Indoor Temperature (OF)
79.0
Environmental Data
Outdoor Temperature (OF)
Altitude (ft)
5000.0
Data Points
Nominal Baseline Adjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-1.7 n/a
n/a
-61.4 -60.1
60.1
1281
1328
-1.9
Ring A
-55.2 -53.9
44.3
1208
1252
-0.1
Ring A
-%1 -48.8
38.7
1129
1171
0.2
Ring
-43.0 -41.8
32.0
1030
1067
2.2
Ring A
-37.9 -36.6
26.4
938
972
2.3
Ring A
-32.4 -31.1
183.1
802
831
-1.9
Ring B
-25.8 -24.5
134.9
689
714
-0.0
Ring B
-20.1 -18.8
91.6
569
590
-0.5
Ring B
-0.9 n/a
n/a
Time Averaging Period: 10
Deviations from Standard RESNET Multi -Point Test - Test Parameters
None
Build
Home Services
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 8/18/2016 Test File: 6744 Snowdon Dr - Magnolia - Techtite
Comments
House to Garage: -45.0 Pa