Loading...
HomeMy WebLinkAbout5809 Northern Lights Dr - Disclosures/Blower Door Test - 07/29/2016BUILDING LEAKAGE TEST Date of Test: 7/29/2016 Test File: 5809 Northern Lights Dr Ryland Homes REM 14.6.2 TECTITE Customer: Ryland Homes Technician: Neal Girard - EnergyLogic Project Number: 42085 Building Address: 5809 Northern Lights Dr Ft Collins, CO 80528 Test Results 1. Airflow at 50 Pascals: 1549 CFM50 (+/- 1.4 %) (50 Pa = 0.2 w.c.) 2.04 ACH50 2. Leakage Area: 85.2 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 73.4 (+/- 24.0 %) Exponent (n) = 0.779 ( +/- 0.063 ) Correlation Coefficient = 0.99675 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 90.3 CFM '0.12ACH 15.1 CFM per person Winter: 169.9 CFM Summer: 106.6 CFM 0.22 ACH 0.14 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 93.2 CFM Base Rate: 93.2 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/29/2016 Test File: 5809 Northern Lights Dr Ryland Homes REM 14.6.2 TECTITE Building Information Volume 45501 Surface Area 9412 Floor Area 4818 �Height 20 # of Bedrooms 6 # of Occupants 6 Year of Construction 2016 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost -Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.03 Heatin a D ea r ee Days 6128 ng uegree uays In Winter Wind Speed n Summer Wind S Design Winter Temp Diff Design Summer Temp Diff Equipment Information 297 7.3 mph 9.4 mph 73 deg F 15 deg F Type Manufacturer T Mod . el Serial - N - urnber -Custom Calibration Date Fan Micromanometer Energy Conservatory Model 3 (11 OV) Energy Conservatory _j DG700 6108-5 1/17/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/29/2016 Test File: 5809 Northern Lights Dr Ryland Homes REM 14.6.2 TECTITE Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (°F) Altitude (ft) 71.0 81.0 4900.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.9 n/a n/a -60.7 -59.7 86.7 -57.0 -56.0 76.7 -53.1 -52.1 65.7 -49.0 -48.0 55.9 -45.0 -43.9 52.3 -40.5 -39.4 43.5 -37.3 -36.3 37.7 -33.1 -32.0 31.4 -1.2 n/a n/a Time Averaging Period: 10 None 1675 1807 1.6 Ring A 1578 1702 0.6 Ring A 1462 1578 -1.3 Ring A 1352 1459 -2.6 Ring A 1309 1412 0.9 Ring A 1197 1292 0.4 Ring A 1116 1205 -0.1 Ring A 1020 1101 0.6 Ring A Deviations from Standard RESNET Muiti-Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/29/2016 Test File: 5809 Northern Lights Dr Ryland Homes REM 14.6.2 TECTITE Comments Connection to: Garage: -49.5 Mechanicals: -50 Pa