Loading...
HomeMy WebLinkAbout602 Buckingham St - Correspondence/Zoning - 07/06/2016011 4-4 ELECTRONIC REVIEW PROJECT COVER SHEET Please check one: o Tenant Finish o New commercial building o New -single family o New multi - family qP LA t Permit #: Date Initialized: ,2-1 2- Li 1= Plan Review: vz� Date:. Zoning Review: Date: Proposed Use: -NOA) It NfA.�j EieLLOiLLM Construction Value: Address: (000 City of Planning, Development c& Transportation Services Frt Collins Community Development & Neighborhood Services 281. North College Avenue Fort Collins, CO 80524 970.416.2740 PLAN REVIEW COMMENT LETTER Plan review for: Permit #B1600121, 602 Buckingham St. Project description: Construction of new building for medical office bldg Date comments sent to applicant: 3/7/2016 Below are the items I need submitted as corrections/revisions for plan review approval. Do not submit entire new sets of plans, just the sheets that have corrections. Current adopted code: 2012 International Building Code. B occupancy, V-B construction type, not fire -sprinkled: 1. Provide an architectural site plan showing distance of building to property lines and to other buildings. Be advised if this building is closer than 60ft to the other buildings on this site it must be fire -sprinkled to maintain the un-limited area used by those existing buildings. 2. The building wall section and insulation does not match the comcheck. Provide correction. 3. Need verification the structural plans meet 100B nominal or 129 Vult wind load. Plans show 100C to ASCE 7-10 and if using that standard must be 129 Vult min. 4. Provide SIP panel specs showing r-value and structural info showing the panels can span 5ft as shown on plans. 5. Exposed wood ceiling must meet a interior finish flame/smoke rating of class C per section 803. 6. Why is mech equipment not shown on the mech room plans? 7. What material is used for the exterior wall air barrier? 8. Submit a. construction waste recycling plan showing how concrete, wood, metal, and cardboard will be recycled. List who will pick up material and what facility they are taken to. Russ Hovland Plans Examiner City of Fort Collins 910-416-2341 rhovland@fcgov.com City of Fort Collins - Building Services COMMERCIAL PLAN REVIEW CHECK LIST 2012 IBC aclix,BC ADDRESS: o Z u C l2 �( PERMIT #: Z Revised 7-20-2015 DOCUMENTS BUILDING PERMIT APPLICATION & PLAN CHECK FEE SITE PLANS C la C� ARCHITECTURAL DRAWINGS C� STRUCTURAL DRAWINGS (i MEP PLANS O x-F V CONTRACTOR LICENSE CHECK � f 7Lk e, CODE DATA �OCCUPANCY CLASS CONSTRUCTION TYPE k AUTOMATIC SPRINKLER SYSTEM dirt LcpS �,( rI� 51� c /' CHAPTER 4 F;;PROVISIONS FOR: MALLS, HIGH RI , ATRIUM, STAGES, THEATERS C o.r cLjG�cK PROVISIONS FOR: HAZARDOUS MATERIALS, PARKING GARAGES, I-2, I-3 CHAPTER 5 F/BUILDING HEIGHT (S) t fIL4*" c O aw HEIGHT INCREASE, SPRINKLER ? ALLOWABLE AREA CD S / Sp Cr m FRONTAGE INCREASE (YARD) SPRINKLER INCREASE (REQUIRES FULL 13 SPRINKLER) MULTI -STORY INCREASE r /� OCCUPANCY SEPARATION L/ !� ACCESSORY, NO SEPARATION NONSEPARATED OCCUPANCIES � GI a CHAPTER 6 CORRECT MATERIALS USED PER TYPE OF CONSTRUCTION RATED CONSTRUCTION PROTECTED CORRECT LOCATION ON PROPERTY WALL PROTECTION G ( f CHAPTER 7 RATED ASSEMBLY REVIEW JF/Gt/yc ASSUMED PROPERTY LINE WALL PROTECTION/OPENING PROTECTION/PARR ET FIREWALL SEPARATION OF BUILDING FIRE BARRIER (OCCUPANCY SEP, EXIT ENCLOSURE, SHAFT) FIRE PARTITIONS (CORRIDORS, DWELLING SEP, ELEV LOBBY) SMOKE BARRIER/SMOKE PARTITION (I-2 & I-3 OCCUPANCY) HORIZONTAL RATED ASSEMBLY PENETRATIONS/OPENING PROTECTION/AIR DUCT SMOKE & FIRE DAMPERS CONCEALED SPACES (FLOOR & ATTIC DRAFTSTOP) CHAPTER 8 TOILET ROOM FLOORS & WALLS NONABSORBENT TO 4FT HIGH CHAPTER 9 -- FIRE CONTAINMENT/FIRE AREA SPRINKLER SYSTEM REQUIRED PER OCCUPANCY 903 STANDPIPE SYSTEM 905 FIRE ALARM REQUIRED (907) SMOKE CONTROL/SMOKE & HEAT VENTS CHAPTER 10 EXITS REQUIRED PER AREAS (OCCUPANT LOAD), PER BUILDING CAM Cam[ 6 CK - r oof ; 1'�9--/e6 c W'? V: f,-3 z f 7. 5 EXIT WIDTH, 2 EXIT SEPARATION, ADDITIONAL EXITS EXIT SIGNAGE, EGRESS ILLUMINATION [�-- ACCESSIBLE MEANS OF EGRESS ALLOWABLE EXIT TRAVEL DISTANCE, DEAD END, INTERVENING RMS COORIDOR, EXIT ENCLOSURE, EXIT PASSAGEWAY (/ DOOR SWING, STAIRS, HANDRAIL, GUARDRAIL, HALLWAY DOOR HARDWARE — NO THUMB TURN LOCKS ON COMMON EXITS �— SPECIAL EXIT REQUIREMENTS PER OCCUPANCY ARCH DETAILS l WALL SECTIONS, ROOF CLASSIFICATION,'MATERIALS L� ROOF DRAINS, OVERFLOWS, ROOF SLOPE, ATTIC ACCESS C: WALL WEATHER RESISTIVE BARRIER SAFETY GLAZING ENERGY CODE: PRESCRIPTIVE IECC �j COMCHECK SPA RATING c.i 5 INSULATION ON PLANS CORRECT, FOUNDATION INSULATION (� LIGHTING PLAN, LIGHTING WATTAGE WORKSHEETS VESTIBULE CHAPTER it 60% OF ENTRANCES ACCESSIBLE ANSI REQUIREMENTS PARKING STRUCTURAL: 30" FROST DEPTH, 30 PSF ROOF LOAD, WIND LOAD 100B, FLOOR LOAD i l? BEAMS, COLUMNS, JOISTS, TRUSSES, BEARING WALLS, WALL BRACING !� SIGNATURE & STAMP ON PLANS MECHANICAL Z-- MECH LAYOUT L� VENTILATION, IMC CHAP4, TOILET EXHAUST FAN TYPE I HOOD, 1—HOUR ENCLOSURE, EXHAUST TERMINATION LOCATION HVAC / MECHANICAL AIR BALANCE REPORT HOLD PLUMBING l FIXTURE COUNT (SEPARATE MENS/WOMENS IF COUNT 16+) �-- PLUMBING LAYOUT, RISER DIAGRAM, FLOOR DRAINS GREASE/SAND/OIL TRAP MED GAS, IPC 1202, NFPA 99C RESTAURANT TOUCH —FREE TOILET FIXTURES ELECTRICAL DONE —LINE CHECK, GFI'S, PANEL CLEARANCE (DOORS) (` EXAM ROOM REDUDANT GROUND, NEC 517 SPECIAL ELEVATOR INSPECTIONS S WELDING / HIGH STRENGTH BOLTING STRUCTURAL MASONRY �— PRE—STRESSED/POST TENSIONED SLABS SPRAY APPLIED FIRE PROOFING VALUATION VALUATION CHECK REVIEWER & DATE APPROVED: F_ -1 home > departments (/departments/) > building services (/building/) > New Construction Permit Fee Schedule Fees are effective January 2, 2015 All new buildings are subject to the following fees: From Building Services Building Permit Fee Schedule (pdf/2015permit-fee-schedule.pdf) Building Permit Capital Imorovement Expansion Fee (MV2015-ciemcf) From Utilities Electric Water Wastewater and Stormwater Fees (http://www.fcgov,com/utilities/business/builders-and- deve loners/ola nt-investme nt-development-fees) BUILDING AND PLAN REVIEW FEES For Residential Over the Counter Type Permits Residential gas logs, wood stoves, air conditioning, furnace replacements, underground sprinklers, water heaters, and electrical service change are $25 per appliance plus City and County use tax. Use the Building Permit Fee WO/Subs for Over the Counter type permits In the Building -Combination Estimate of Fees below (those that do not have a Flat $25 permit fee). The Building Permit Fee W/Subs Is applicable for fees associated with all other permit types. City and County use taxes apply to both tables. THERE IS NO PLAN CHECK FEE ON SIGN PERMITS (REGARDLESS OF THEIR VALUATION), AND THERE IS NO PLAN CHECK FEE FOR VALUATIONS UP TO AND INCLUDING $3,000 ON ANY PERMIT TYPE. Building -Combination Estimate of Fees Valuation: $ ,625775 Bldg Permit Fee WO/Subs: Bldg Permit Fee W/Subs: Permit Fees: $2,855.50 Permit Fees: $3,854.93 Plan Check Fee: $1,856.08 Plan Check Fee: $1,856.08 City Sales/Use Tax: F $12,o4617, City Sales/Use Tax: $12,046.17. County Sales Tax: F $2,033.77 County Sales Tax: $2,033.77 Total: $18,791.51 Total: $19,790.94 HOW TO CALCULATE BUILDING PERMIT FEES ............. _.. o_....... I Total Valuation .. ......_....._. ._ . _.. ........ .._.._...... ._._......_ _... Review .__._.... ... ..........___.......__... Building Permit Fee Building $1 to _Plan None $25.00 $500 .._$_2....5_ _-None _ .f. . $501 [_o,_- f_or_ the rst_$5.0.0_ plus $_2...7_5—r.. e.a._c.h_ $2,000 additional $100 or fraction thereof to and .._..___..._.._. ..........__...no _...__......... _ ._...._. -v—____.__...._ ._ _._.__.. _ __._.._ -plan--view -fee- including $2,000 _ __ __._.._ . .___ _ ._..._.._.. .__ .... _._.__..__ _ $2,001 to for valuations $3,000 and under. No plan re r Use the formula In the column to the left, $25,000 Over $3,000 -- $66.25 for the first $2,000 plus $10.25 but take this total times 1.35 for each additional $1,000 fraction thereof to and including $25,000. Take this total times .65 I $25,001 to _ _ _ _ _---- $302.00 for the first $25,000 plus $8.50 for each Use the formula in the column to the left, $50,000 additional $1,000 or fraction thereof to and including but take this total times 1.35 $50,000 Take this total times .65 $50,001 to $514.50 for the first $50,000 plus $6 for each Use the formula in the column to the left, 1 $100,000 additional $1,000 or fraction thereof to and including but take this total times 1.35 $100,000. -.____......_....__....._._.__.._..__....._.___ Take this total times .65 $100,001 to .._.—._._.......- _.___.__ P_._..$ .__._._.__­ $814.50 for the first 100,000 lus 4.00 for each _ Use the formula in the column to the left, $500,000 additional $1,000 or fraction thereof. but take this total times 1.35 Take this total times .65 $500,001 to $2414.50 for the first $500 000 plus $3 50 for each _ Use the formula in the column to the left, $1,000,000 additional $1,000 or fraction thereof. but take this total times 1.35 Select Language I Building Codes & Standards (/building/codes.php) Commercial & Muld-family Permit Requirements (/building/comm- requirements.php) Contractor Licensing (/bui (ding/contracto r.php) Construction Activity Reports (http://citydocs.kgov.com/? Green Codes & Energy Forms Vbui (ding/greencla sses. php) Green Building (http://www.fcgov.com/enviro/green- building.phip) Inspections (/building/inspections.php) Permit Applications & Forms (/building/application. php) Permit Fees (/building/fee-calc- 2012.php) Residential Permit Requirements (/building/res-requirements. php) Submittal Requirements (/building/submit, php) Solar Permits and Application (/building/res-requirements.php) Zoning Fences & Walls (/building/fences.php) Home Businesses (/building/homebusi ness. php) i Land Use Code (/cityclerk/codes.php) f Land Use/Zoning District Matrix (PDF) (/building/pdf/mem atrixmarch20l2.pdf) Minor Amendment Application (http://www.fcgov.com/zoning/what.php) Occupancy Limits & Enforcement (http://www.fcgov.com/occupancy) Signs, Banners & Pennants (/building/banners.php) Zoning Variances (http://www.fcgov.com/zoning/what.php) , Zoning Map (http://www.fcgov.com/zoning/map- instructions.php) Other Info About Us/Contact Us (/building/contact php) Building Review Board (http://www.fcgov.com/cityclerk/building- review.php) ....._............._......__........._._-- Take this total times .65 _..__............_........_...__..............._...._......._.__.._..._..._..__._..........._._.__....._----..._...._......_._......._.__._..__._..........-----.__.__.. i Zoning Board of Appeals $1,0-00,001 to $_4,164.50 for the first $1,000,000 plus $2.50 for each Use the formula In the column to the left, (http.//www.fcgov.mm/a derk/zonmg- ty $10,000,000 additional $1,000 or fraction thereof. but take this total times 1.35 appeals.php) this total times .65 $10,000,001 _Take $26,664.50 for the first $10,000,000 plus $1.00 for Use the formula in the column to the left, and up each additional $1,000 or fraction thereof. but take this total times 1.35 Take this total times .65 Website Navigation City Services (/cityservices/) News/Events (/news/) City Leadership (/cityleadership/) Public Records (/publicrecords/) jobs (/jobs/) Business (/business/) Contact Us (/contactus/) Ijelp (/help/) Mobile Website (http://m.fcgov.com/) QR Code / MS Tag for this Page (/tags -codes/? url=http%3A%2F%2Fwww.fcgov.com%2Fbuildi ng%2Ffee- calc-2012.php) denotes Accesskev (Loal.oho? cmd=accessibility#accesskevl) Our Organization Mission, Vision, Values (/citymanager/vmv.php) "World Class People" (/wcp/) City Budget (/budget/) Open Book (/openbook/) Sustainability (/sustainability/) Environmental Portal (/enviro/) Connect Social Media and More (/connect/) Legal General Disclaimer (/legal.php) Copyright (/legal.php? cmd=copyright) Privacy (/legal.php?cmd=privacy) Non-discrimination (/legal.php? cmd=non-discrimination) Accessibility (/legal.php? cmd=accessibility)