Loading...
HomeMy WebLinkAbout2635 Geranium Ln - Disclosures/Blower Door Test - 06/13/2016BUILDING LEAKAGE TEST Date of Test: 6/13/2016 Customer: Century Communities Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Test File: 2635 Geranium Lane Technician: Michael Broussard Project Number: Building Address: 2635 Geranium Lane Fort Collins, Colorado 2036 CFM50 (+1- 43.3 %) 2.97 ACH50 112.0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 132.1 ( +/- 890.9 %) Exponent (n) = 0.699 ( +/- 2.266 ) Correlation Coefficient = 0.96898 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Reduced Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/13/2016 Test File: 2635 Geranium Lane Building Information Location Climate Information Volume 41192 Surface Area FloorArea Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - No Text No Text