HomeMy WebLinkAbout3339 W Elizabeth St - Disclosures/Final Energy - 06/09/20160 w Leakage Property Richmond American Homes 3339 W Elizabeth st Fort Collins, CO 80521 Weather:Ft. Collins, CO D-193bR RAH 3339 W Elizabeth st D193bR_Final_060916.b1g Whole House Infiltration Organization Home Performance Solutions 720-985-8445 Michael Broussard Builder Richmond American Homes HERS Confirmed Rating 6/9/16 Rating No:HPS-060916 RaterID:6104548 Blower Door Test Heating i Cooling Natural ACH 0.14 j 0.11 ACH @ 50 Pascals 3.001 3.001 CFM @ 25 Pascals i 1124 1124 CFM C 50 Pascals j 1763. 1763 , Eff. Leakage Area (sq.in) 96.8 ` 96.8 Specific Leakage Area 0.00017 0.0001711 ELA/100 sf shell (sq.in) j 1.241 1.24 Duct Leakage Leakage to Outside Units bsmnt CFM @ 25 Pascals I 151 i CFM25 / CFMfan 0.0119; CFM25 / CFA 0.0038 ' CFM per Std 152 N/A CFM per Std 152 / CFA• N/A CFM @ 50 Pascals i 241 Eff. Leakage Area (sq.in) 1.29 Thermal Efficiency , N/A! Total Duct Leakage Units CFM25/CFA; Total Duct Leakage 0.0241 Ventilation Mechanical Air Cycler: ASHRAE; Sensible Recovery Eff. (%) i 0.0: 62.2-2010 Total Recovery Eff. (a) 0.0 Rate (cfm) 120i 69 Hours/Day 16.01 24.0 Fan Watts i 40.0 , Cooling Ventilation Natural Ventilation; ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole -building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2015 Noresco, Boulder, Colorado. Property Richmond American Homes 3339 W Elizabeth st Fort Collins, CO 80521 Weather:Ft. Collins, CO D-193bR RAH_3339 W Elizabeth st_D193bR_Final_060916.big Organization Home Performance Solutions 720-985-8445 Michael Broussard Builder Richmond American Homes HERS Confirmed Rating 6/9/16 Rating No:HPS-060916 RaterID:6104548 Emissions By End -Use Carbon Dioxide (CO2) - tons/year Heating 2.9 Cooling 0.5 WaterHeating 1.1 LightsAppliances 7.8 Photovoltaics 0.0 Total 12.3 Sulfur Dioxide (S02) - lbs/year Heating 0.5 Cooling 1.1 WaterHeating 0.0 LightsAppliances 17.1 Photovoltaics 0.0 Total 18.7 Nitrogen Oxide (NOx) - Ibs/year Heating 7.4 Cooling 1.4 WaterHeating 2.7 LightsAppliances 22.7 Photovoltaics 0.0 Total 34.2 Site -to -source energy multipliers and air emission data were taken from the US EPA eGRID2012 database. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2015 Noresco, Boulder, Colorado. Property Organization HERS Richmond American Homes Home Performance Solutions Confirmed Rating 3339 W Elizabeth st 720-985-8445 6/9/16 Fort Collins, CO 80521 Michael Broussard Rating No:HPS-060916 RaterID:6104548 Weather:Ft. Collins, CO D-193bR RAH_3339 W Elizabeth st_D193bR_Final-060916.big Elements Shell UA Check Ceilings: Above -Grade Walls: Windows and Doors: Basement Walls: Builder Richmond American Homes Overall UA (Design must be equal or lower): Mandatary Requirements Shell UA Check Duct Insulation R-Value Check (per Section 403.2.1) Window U-Value and SHGC Check (per Section 402.5) Home Infiltration (Section 402.4.1.2) Duct Leakage (Section 403.2.2) Mechanical Ventilation (Section 403.6) Mechanical Ventilation Fan Efficacy (Section 403.6.1) Mandatory Requirements Check Box (IECC 12) Insulation Levels 2012 IECC As Designed 50.8 37.9 102.0 90.0 109.8 98.6 88.3 64.3 350.8 290.7 PASSES PASSES PASSES PASSES PASSES PASSES PASSES PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5B. (Section 402, International Energy Conservation Code, 2012 edition.) In fact, this home surpasses the requirements by 17.1%. Name Michael Broussard Signature Organization Home Performance Solutions Date13 June 2016 � I REM/Rate - Residential Energy Analysis and Rating Software 04.6.1 This information does not constitute any warranty of energy cost or savings. (0 1985.2015 Noresco, Boulder, Colorado. 2012 IECC Certificate 3339 W Elizabeth st, Fort Collins, CO 80521 Building Envelope Insulation, Ceiling R-50.0 Above Grade Walls R-21.0 Foundation Walls R-19.0 Exposed Floor NA Slab R•0.0 Edge, R-0.0 Under Infiltration Htg: 1763 Clg: 1763 CFM50 Duct NA Total Duct Leakage 94.00 CFM 25 Pascals ..- Window.Data U-Factor SHGC Window 0.300 0.330 Mechanical Equipment. HEAT: Fuel -fired air distribution, Natural gas, 96.1 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.70 EF, 50.0 Gal. Builder o(Design Professional.. Signature RFAVRate Resrctenna, knewy Analysis an(i tiating sattware V14.6.1