HomeMy WebLinkAbout3339 W Elizabeth St - Disclosures/Final Energy - 06/09/20160
w Leakage
Property
Richmond American Homes
3339 W Elizabeth st
Fort Collins, CO 80521
Weather:Ft. Collins, CO
D-193bR
RAH 3339 W Elizabeth
st D193bR_Final_060916.b1g
Whole House Infiltration
Organization
Home Performance Solutions
720-985-8445
Michael Broussard
Builder
Richmond American Homes
HERS
Confirmed Rating
6/9/16
Rating No:HPS-060916
RaterID:6104548
Blower Door Test
Heating i Cooling
Natural ACH
0.14 j
0.11
ACH @ 50 Pascals
3.001
3.001
CFM @ 25 Pascals
i 1124
1124
CFM C 50 Pascals
j 1763.
1763 ,
Eff. Leakage Area (sq.in)
96.8 `
96.8
Specific Leakage Area
0.00017
0.0001711
ELA/100 sf shell (sq.in)
j 1.241
1.24
Duct Leakage Leakage to Outside Units
bsmnt
CFM @ 25 Pascals
I 151
i
CFM25 / CFMfan
0.0119;
CFM25 / CFA
0.0038 '
CFM per Std 152
N/A
CFM per Std 152 / CFA•
N/A
CFM @ 50 Pascals
i 241
Eff. Leakage Area (sq.in)
1.29
Thermal Efficiency
, N/A!
Total Duct Leakage Units
CFM25/CFA;
Total Duct Leakage
0.0241
Ventilation Mechanical
Air Cycler:
ASHRAE;
Sensible Recovery Eff. (%)
i 0.0:
62.2-2010
Total Recovery Eff. (a)
0.0
Rate (cfm)
120i
69
Hours/Day
16.01
24.0
Fan Watts
i 40.0 ,
Cooling Ventilation
Natural Ventilation;
ASHRAE 62.2 - Ventilation Requirements
The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole -building'
requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent
mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours
per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to
the appropriate standard.
REM/Rate - Residential Energy Analysis and Rating Software v14.6.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2015 Noresco, Boulder, Colorado.
Property
Richmond American Homes
3339 W Elizabeth st
Fort Collins, CO 80521
Weather:Ft. Collins, CO
D-193bR
RAH_3339 W Elizabeth
st_D193bR_Final_060916.big
Organization
Home Performance Solutions
720-985-8445
Michael Broussard
Builder
Richmond American Homes
HERS
Confirmed Rating
6/9/16
Rating No:HPS-060916
RaterID:6104548
Emissions By End -Use
Carbon Dioxide (CO2) - tons/year
Heating
2.9
Cooling
0.5
WaterHeating
1.1
LightsAppliances
7.8
Photovoltaics
0.0
Total
12.3
Sulfur Dioxide (S02) - lbs/year
Heating
0.5
Cooling
1.1
WaterHeating
0.0
LightsAppliances
17.1
Photovoltaics
0.0
Total
18.7
Nitrogen Oxide (NOx) - Ibs/year
Heating
7.4
Cooling
1.4
WaterHeating
2.7
LightsAppliances
22.7
Photovoltaics
0.0
Total
34.2
Site -to -source energy multipliers and air emission data were taken from the US EPA eGRID2012 database.
REM/Rate - Residential Energy Analysis and Rating Software v14.6.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2015 Noresco, Boulder, Colorado.
Property Organization HERS
Richmond American Homes Home Performance Solutions Confirmed Rating
3339 W Elizabeth st 720-985-8445 6/9/16
Fort Collins, CO 80521 Michael Broussard Rating No:HPS-060916
RaterID:6104548
Weather:Ft. Collins, CO
D-193bR
RAH_3339 W Elizabeth
st_D193bR_Final-060916.big
Elements
Shell UA Check
Ceilings:
Above -Grade Walls:
Windows and Doors:
Basement Walls:
Builder
Richmond American Homes
Overall UA (Design must be equal or lower):
Mandatary Requirements
Shell UA Check
Duct Insulation R-Value Check (per Section 403.2.1)
Window U-Value and SHGC Check (per Section 402.5)
Home Infiltration (Section 402.4.1.2)
Duct Leakage (Section 403.2.2)
Mechanical Ventilation (Section 403.6)
Mechanical Ventilation Fan Efficacy (Section 403.6.1)
Mandatory Requirements Check Box (IECC 12)
Insulation Levels
2012 IECC As Designed
50.8
37.9
102.0
90.0
109.8
98.6
88.3
64.3
350.8
290.7
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation
Code based on a climate zone of 5B. (Section 402, International Energy Conservation Code, 2012 edition.) In fact, this home
surpasses the requirements by 17.1%.
Name Michael Broussard Signature
Organization Home Performance Solutions Date13 June 2016
� I
REM/Rate - Residential Energy Analysis and Rating Software 04.6.1
This information does not constitute any warranty of energy cost or savings.
(0 1985.2015 Noresco, Boulder, Colorado.
2012 IECC Certificate
3339 W Elizabeth st, Fort Collins, CO 80521
Building Envelope Insulation,
Ceiling R-50.0
Above Grade Walls R-21.0
Foundation Walls R-19.0
Exposed Floor NA
Slab R•0.0 Edge, R-0.0 Under
Infiltration Htg: 1763 Clg: 1763 CFM50
Duct NA
Total Duct Leakage 94.00 CFM 25 Pascals
..-
Window.Data U-Factor SHGC
Window 0.300 0.330
Mechanical Equipment.
HEAT: Fuel -fired air distribution, Natural gas, 96.1 AFUE.
COOL: Air conditioner, Electric, 13.0 SEER.
DHW: Conventional, Natural gas, 0.70 EF, 50.0 Gal.
Builder o(Design Professional..
Signature
RFAVRate Resrctenna, knewy Analysis an(i tiating sattware
V14.6.1