HomeMy WebLinkAbout3803 Precision Dr - Disclosures/Blower Door Test - 06/15/2016 (2)BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 Fort Collins, CO 80525 Email: BuildingPerformance@GSServices.com Website: GSServices.com Date of Test: 6/15/2016 Test File: Landmark - 3803 Precision Dr. - Unit B - Bordeaux -BDma Customer: Landmark Homes Technician: Paul Higman Project Number: Building Address: 3803 Precision Dr. Unit B Bordeaux Fort Collins, CO 80528 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curare: 4. Test Settings: 5. Accuracy Level Infiltration Estimates 951 CFM50 (+/- 1.8 %) 2.93 ACH50 52.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 9.2 ( +/- 14.1 %) Exponent (n) = 1.186 ( +/- 0.039 ) Correlation Coefficient = 0.99946 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 45.0 CFM 0.14 ACH Winter: 63.7 CFM Summer:. 46.7 CFM 0.20 ACH 0.14 ACH Pul Digitally signed by: Paul ON, a -DN: C=Paul Higman email pigman@gs-email.com C ' "° =1D O = GS Services LTD H i g m a nJ �Q 2016.06.23 08:45:13 - GS Sel�tces BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/15/2016 Test File: Landmark - 3803 Precision Dr. - Unit B - Bordeaux -BDma Building Information Volume 19488 Surface Area FloorArea 13" Height 10 # of Bedrooms # of Occupants Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 GS Services �:---. - BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/15/2016 Test File: Landmark - 3803 Precision Dr. - Unit B - Bordeaux -BDma Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 62.0 76.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.5 n/a n/a -61.1 -59.6 30.6 1008 1187 1.4 Ring A -56.2 -54.7 236.8 911 1073 1.4 Ring B -49.8 -48.3 166.5 765 901 -1.3 Ring B -44.0 -42.5 125.1 664 782 -0.3 Ring B -38.0 -36.5 84.3 546 643 -1.8 Ring B -31.7 -30.2 53.3 435 512 -2.0 Ring B -25.5 -24.0 33.0 343 404 1.5 Ring B -21.8 -20.3 150.4 280 330 1.1 Ring C -1.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. GSel-wcss BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/15/2016 Test File: Landmark - 3803 Precision Dr. - Unit B - Bordeaux -BDma Comments House WRT Garage = detached