HomeMy WebLinkAbout2720 Council Tree Ave - Special Inspections/Field Verification - 06/01/2016El FORT COLLINUMIDWEST INC. 3818 PLATTE CT. FORT COLLINS, CO. 80526 PHONE (970) 223-5421 FAX (970) 225-2814 TESTING, ADJUSTING & BALANCING OF H.V.A.C. & HYDRONIC SYSTEMS GENERAL INFORMATION PROJECT LOCATION . ARCHITECT MECHANICAL ENGINEER MECHANICAL CONTRACTOR BALANCING TECHNICIAN DATE INSTRUMENTS USED VELGRID FLOW HOOD ANEMOMETER SPEED INDICATOR AMMETER VOLTMETER POWER HARMONICS ANALYZER DIGITAL MICROMANOMETER PRESSURE GAGE PRESSURE GAGE -DIFFERENTIAL ULTRASONIC FLOW METER THERMOMETERS IAQ METER CO2 & CO ii'ko HIMALAYAN BISTRO FRONT RANGE VILLAGE, FORT COLLINS, CO. WILLIAM C. HARRISON JUNE 2016 SHORTRIDGE AIRDATA MULTIMETER SHORTRIDGE AIRDATA MULTIMETER SHIMPO DIGITAL TACHOMETER DT205B FLUKE 36 TRUE RMS FLUKE 36 TRUE RMS SHORTRIDGE AIRDATA MULTIMETER PROJECT ALTITUDE 5000' SHORTRIDGE BAROMETRIC CORRECTION IS AUTOMATIC. WILLIAM C. HARRISON IS A MEMBER OF THE ASSOCIATION OF ENERGY ENGINEERS, AND IS A CERTIFIED TESTING, ADJUSTING AND BALANCING PROFESSIONAL. i:. ... ..:. x.:. +.,� � .: .W ., .. ., of .-p.ve. }:Y:•�. 'hi �"4 �i.G''-:. �:y.�n ♦ r.�.�. �.rr�.r::��..ri�' __. '.•.l•. •r- _.-.. ......, _.,� +.)..'s _.._.. •1.'R ..: _.--._"a_r.ri �.- •2.v.: _.-. �,:,.m' _-.. 'L:.v:c y,- �>-\.s __-_ .,',i.y'�_-_-. .�.,e �_. �ls�"�_"`�. �. ._�, __,_� ..�: ._.�..hFs _—_ ...... ___. :\ "7 •fY $uGARMN coAsutTr*0 certifies that William C Harrison has compteted the prescr'bed stavwdards for certi f�cattov+. Lw the fvtol of Tesem@-Adjust4wg--aLQ VLr,' @ of HvAc systems awd is herebd gramed the tf�tLe of CERTIFIED TESTING -ADJUSTING -BALANCING PROFESSIONAL :.;1S; Mt,ff, CTABO A Standard of Professional Achievement Valid for Life FORT COLLINS/MIDWEST, INC. RECAP SHEET PROJECT HIMALAYAN BISTRO OPENING TYPE SUPPLY FCU-1 SUPPLY FCU-2 TOTAL SUPPLY MAU-1 SUPPLY FCU-1 MIN. O.S.A. SUPPLY FCU-2 MIN. O.S.A. TOTAL O.S.A. EXHAUST KEF-1 EXHAUST KEF-2 EXHAUST KETTLE FAN EXHAUST MAIN BUILDING TOTAL REQ'D CFM 1995 2000 3995 4990 475 475 5940 2000 2000 700 300 5000 FINAL REMARKS CFM 1960 1920 3880 4930 450 495 5875 2154 2181 630 0 i 301 5266 PAGE 2 FORT COLLINS/MIDWEST, INC. EQUIPMENT DATA PROJECT HIMALAYAN BISTRO (A) FAN UNIT # FCU-1 MAKE CARRIER MODEL # 39SHK05-6G-19E SERIAL # 201 OR33954 RATING 2000 CFM @ 0.50" ESP (B) MOTOR MARATHON TYPE NOT GIVEN HORSEPOWER 1 MEAS. VOLTS (UL) 487/488/486 MEAS. VOLTS (L/G) 281/281/280 INITIAL AMPS FINAL AMPS 1.3/1.4/1.4 (C) STARTER NONE EXIST. THERMALS REQ'D. THERMALS REMARKS BUILT IN OVERLOAD PROTECTION (D) SHEAVES RATED PF/EFF NOT GIVEN RATED SPEED 1725 RATED VOLTS 208-230/460 RATED AMPS 3.6-3.8/1.9 PHASE 3 SERVICE FACTOR 1.15 FRAME 56 SIZE EXIST AMP RATING REQ'D AMP RATING DRIVEN AK64 H BORE SIZE 3/4" DRIVER 1VL40 BORE SIZE 5/8" DRIVEN CHANGE BELTS/SIZE 4L460 DRIVER CHANGE BELT CHANGE A40 INITIAL RPM 738 FINAL RPM 738 (E) STATIC PRESSURE IN INCHES FILTER IN - 0.016 OUT NO ACC. DROP HEAT COIL IN DROP COOL COIL IN NO ACC. OUT - 0.339 DROP 0.323 FAN IN - 0.339 OUT 0.718 RISE 1.057 (F) MINIMUM O.S.A. REQ'D 0.545 SQ. FT. X 872 FPM = 475 CFM FINAL 0.545 SQ. FT. X 826 FPM = 450 CFM PAGE 3 FORT COLLINS/MIDWEST, INC. EQUIPMENT DATA PROJECT HIMALAYAN BISTRO (A) FAN UNIT # FCU-2 MAKE CARRIER MODEL # 39SHK05-6G-16E SERIAL # 201 OR33955 RATING 2000 CFM @ 0.50" ESP (B) MOTOR MARATHON RATED PF/EFF NOT GIVEN TYPE NOT GIVEN RATED SPEED 1725 HORSEPOWER 1 RATED VOLTS 208-230/460 MEAS. VOLTS (L/L) 487/488/485 RATED AMPS 3.6-3.8/1.9 MEAS. VOLTS (L/G) 281/281/281 PHASE 3 INITIAL AMPS SERVICE FACTOR 1.15 FINAL AMPS 1.4/1.4/1.4 FRAME 56 (C) STARTER NONE SIZE EXIST. THERMALS EXIST AMP RATING REQ'D. THERMALS REQ'D AMP RATING REMARKS BUILT IN OVERLOAD PROTECTION (D) SHEAVES DRIVEN AK64 H BORE SIZE 3/4" DRIVER 1VL44 BORE SIZE 5/8" DRIVEN CHANGE BELTS/SIZE 41-460 DRIVER CHANGE BELT CHANGE AX42 INITIAL RPM 1000 FINAL RPM 807 (E) STATIC PRESSURE IN INCHES FILTER IN - 0.036 OUT NO ACC. DROP HEAT COIL IN 0 DROP COOL COIL IN NO ACC. OUT - 0.423 DROP 0.387 FAN IN - 0.423 OUT 0.202 RISE 0.625 (F) MINIMUM O.S.A. REQ'D 0.545 SQ. FT. X 872 FPM = 475 CFM FINAL 0.545 SQ. FT. X 908 FPM = 495 CFM PAGE 5 FORT COLLINSIMIDWEST, INC. EQUIPMENT DATA PROJECT HIMALAYAN BISTRO (A) FAN UNIT # MUA-1 MAKE CAPTIVE AIR MODEL # A4-E1000-920 SERIAL # NOT GIVEN RATING 6000 CFM @ 0.750" W.C. (B) MOTOR WEG TYPE NOT GIVEN HORSEPOWER 3.0 MEAS. VOLTS (UL) 484/485/487 MEAS. VOLTS (UG) 280/278/280 INITIAL AMPS 5.3/5.3/5.4 FINAL AMPS 5.3/5.3/5.4 (C) STARTER ALLEN BRADLEY EXIST. THERMALS 4.5-6.3 REQ'D. THERMALS REMARKS (D) SHEAVES RATED PF/EFF 82.5/0.72 RATED SPEED 1730 RATED VOLTS 208-230/460 RATED AMPS 8.70-9.50/4.75 PHASE 3 SERVICE FACTOR 1.15 FRAME E56 SIZE 193-K EXIST AMP RATING 4.75 REQ'D AMP RATING DRIVEN 2BK 90 (H) BORE SIZE HX 1 7/16" DRIVER 2VP42 BORE SIZE 7/8" DRIVEN CHANGE BELTS/SIZE BX80X2 DRIVER CHANGE BELT CHANGE INITIAL RPM 603 FINAL RPM 603 (E) STATIC PRESSURE IN INCHES FILTER NONE HEAT ELEMENT IN - 0.385 OUT - 0.612 DROP 0.227 COOL MEDIA IN - 0.027 OUT - 0.385 DROP 0.360 FAN IN - 0.612 OUT 0.312 RISE 0.924 (F) REMARKS PAGE 7 No Text No Text No Text