HomeMy WebLinkAbout3839 Precision Dr - Disclosures/Blower Door Test - 05/03/2016GS`rv��s Date of Test: 5/3/2016 Customer: Landmark Homes Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST GS Services LTD 2000 S. College Ave #308 Fort Collins, CO 80525 Test File: Landmark Home 3839 Precision DrA-BD Technician: Paul Higman Project Number: Building Address: 3839 Precision UnitA Fort Collins, CO 80528 1037 CFM50 (+/- 0.7 %) 2.94 ACH50 0.4412 CFM50/ft2 floor area 52.2 in2 (+/- 4.1 %) Canadian EgLA @ 10 Pa 18.5in2(+/-6.5%) LBLELA@4Pa Flow Coefficient (C) = 14.3 ( +/-10.1 %) Exponent (n) = 1.095 ( +/- 0.026 ) Correlation Coefficient = 0.99800 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 19.6 CFM 0.06 ACH 2. Estimated Design Infiltration Rate: Winter: 36.8 CFM Summer: 23.1 CFM 0.10 ACH 0.07 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul; Higman D.k;SCN = Paul Fligman C = U igma;n -; Date: 2016.05.06 06: 59 52-06'00' GSSp'rW- es. BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit C - BDma Building Information Volume_ 21489 Surface Area Floor Area 2223 . .. . ...... . Height 9 #of Bedrooms # of Occupants Year of Construction [Wind �S Shield Heating and Cooling Cost and Efficiency Information I Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information 'Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (11 OV) Default 19028-7 Micromanometer Energy Conservatory DG700 GS; S^ere, --� BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit C - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 61.0 57.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.3 n/a n/a -60.5 -60.3 37.8 1118 1170 -1.6 Ring A -54.8 -54.6 31.1 1016 1064 -2.3 Ring A -48.7 -48.5 245.3 927 970 -1.0 Ring B -42.1 -41.9 193.4 824 863 0.3 Ring B -36.7 -36.5 165.6 763 799 5.0 Ring B -30.5 -30.3 115.4 638 668 3.6 Ring B -24.0 -23.8 70.0 498 521 0.3 Ring B -18.3 -18.1 39.3 374 391 -3.9 Ring B -0.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None S2iixCS BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit C - BDma Comments House WRT Garage = detached BUILDING LEAKAGE TEST `'; ` GS Services Ltd er M c �r 2000 S. College Ave #308 . •: w. �• —" Fort Collins, CO 80525 -'` Email: BuildingPerformance@GSServices.com Website: GSServices.com Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Bordeaux - Unit D - BDma Customer: Landmark Homes Technician: Project Number: Building Address: 3839 Precision Dr. Unit D Fort Collins, CO CO Test Results 1. Airflow at 50 Pascals: 971 CFM50 (+/- 2.8 OX (50 Pa = 0.2 w.c.) 2.99 ACH50 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level 53.4 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 20.6 (+/- 20.5 %) Exponent (n) = 0.984 ( +/- 0.057 ) Correlation Coefficient = 0.99834 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 'Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1., Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 44.6 CFM 0.14 ACH Winter: 65.1 CFM Summer: 47.7 CFM 0.20 ACH 0.15 ACH Digitally signed by: Paul Paul Higman 1J1N-.1tN = Paul Higman C igman =us -.Date. 2016.05.06 07:56:. 49 -06'00' .Gs. S BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Bordeaux - Unit D - BDma Building Information [Wdurne Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Const ruction [Wind Shield Heating and Cooling Post and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days j 297 Design Winter Wind Speed 7.3 - mph Design Summer Wind Speed 9.4 mph i Design Winter Temp Diff 73 deg F Design Summer Temp Diff j 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Datel Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatoryl 69700 19028-7 GS `Ser pes 1 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Bordeaux - Unit D - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 68.0 57.0 h__5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure. Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.6 n/a, n/a -60.8 -59.5 36.9 -56.0 -54.7 29.9 -49.4 -48.1 211.3 -43.8 -42.5 173.1 -37.5 -36.2 137.6 -31.0 -29.7 90.0 -25.7 -24.4 59.9 -19.4 -18.1 30.5 -1.0 n/a n/a Time Averaging Period: 10 None 1104 1162 0.8 Ring A 997 1049 -1.1 Ring A 861 906 -3.0 Ring B 780 821 -0.8 Ring B 696 732 3.7 Ring B 564 593 2.1 Ring B 461 485 1.3 Ring B 330 347 -2.8 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters s + GS S2Y�TIS BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Bordeaux - Unit D - BDma Comments House WRT Garage = detached BUILDING LEAKAGE TEST GS Services Ltd S ` S �iVs 2000 S. College Ave #308 -�-:w - Fort Collins, CO 80525 Email: BuildingPerformance@GSServices.com Website: GSServices.com Date of Test: 5/2/2016 Customer: Landmark Homes ;.; Test File: Landmark - 3839 Technician: Project Number: Precision Dr.-="Ch6nin `Blanc - Unit E - BD1 Building Address: 3839 Precision Dr. Unit E Fort Collins, CO 80528 Test Results 1. Airflow at 50 Pascals: 1131 CFM50 (+/- 1.5 %) (50 Pa = 0.2 w.c.) 2.77ACH50 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level 62.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 85.9 (+/- 10.4 %) Exponent (n) = 0.659 ( +/- 0.029 ) Correlation Coefficient = 0.99904 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 51.9 CFM 0.13ACH 2. Estimated Design Infiltration Rate: Winter: 75.8 CFM Summer: 55.6 CFM 0.19 ACH 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Pau I Digitally signed by: Paul Higman .�..Dk;6N = Paul ��� Higman C = US igman.. Date. 2016.05.06 08: ' . 00.20-06'00' 5.ws BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Chenin Blanc - Unit E - BDI .Building Information Volume 24476 Surface Area Floor Area 2532 Height 9 # of Bedrooms 2 2015 # of Occupants Year of Construction M Wind Shield Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost . . ... . .. ............ Heating Efficiency % Cooling Fuel Cost Cooling SEER Type Fan Location Climate Information Ventilation Weather Factor Energy Climate Factor Heating Degree Days Cooling Degree Days Design Winter Wind Speed Design Summer Wind Speed Design Winter Temp Diff Design Summer. Temp Diff Equipment Information Manufacturer Energy Conservatory Micromanometer I Energy Conservatory Model 3 (11 OV) DG700 Serial Number 19028-7 17.00 6128 297 7.3 mph 9.4 mph 73 deg F 15 deg F Custom Calibration Date Default 9/9/2014 5,.YeS BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Chenin Blanc - Unit E - BD1 Depressurization Test: Environmental Data Indoor Temperature (A°F) I Outdoor Temperature (A°F) Altitude (ft) 52.0 -_ 57.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 1.0 n/a n/a -58.8 -60.3 47.8 -53.3 -54.7 41.3 -47.0 -48.5 34.5 -40.8 -42.2 30.3 -35.1 -36.5 233.4 -28.8 -30.2 175.4 -22.8 -24.2 127.9 -15.6 -17.0 85.3 1.8 n/a n/a Time Averaging Period: 0 None 1253 1285 0.5 Ring A 1166 1195 -0.4 Ring A 1068 1095 -1.1 Ring A 1003 1028 1.6 Ring A 904 927 0.9 Ring B 785 805 -0.8 Ring B 671 688 -1.9 Ring B 549 563 1.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/3/2016 Test File: Landmark Home 3839 Precision DrA-BD Building Information Volume 21150 1 Surface Area 2350 Height 20 # of Bedrooms 2 # of Occupants . Year of Construction - Wind Shield 2013 M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas I Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information [V—entilation WeatherFactor0.8-7— Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 29 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff Design Summer Temp Diff 73 deg F 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Fan Energy Conservatory Model 3 (110V) 9876 Default Micromanometer Energy Conservatory D9700 .... .. `S.� BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Chenin Blanc - Unit E - BD1 / Comments House WRT Garage =detached ✓/ S``S-�rV�G@�S BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/3/2016 Test File: Landmark Home 3839 Precision DrA-BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) 71.0 78.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.3 n/a n/a -60.2 -60.0 46.5 1236 1244 -1.7 Ring A -55.0 -54.8 39.5 1142 1150 0.3 Ring A -50.5 -50.3 33.1 1048 1055 1.1 Ring A -45.1 -44.9 26.6 941 947 2.8 Ring A -40.0 -39.8 182.2 800 805 -0.3 Ring B -35.4 -35.2 143.2 710 715 1.2 Ring B -30.1 -29.9 88.1 558 562 -4.9 Ring B -25.5 -25.3 65.8 483 486 -1.1 Ring B -20.1 -19.9 40.1 378 380 0.7 Ring B -0.1 n/a n/a Deviations from Standard CGSB - Test Parameters - n value (1.095) outside of acceptable limits. GS Sexxces BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/3/2016 Test File: Landmark Home 3839 Precision DrA-BD Comments . House WRT Garage = detached garage ✓ BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 --�—�- T-` - Fort Collins, CO 80525 Email: BuildingPerformance@GSServices.com Website: GSServices.com Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit B - BDma Customer: Landmark Homes Technician: Project Number: Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. 'Test Settings: 5. Accuracy Level Building Address: 3839 Precision Dr. Unit B Fort Collins, CO 80528 1026 CFM50 (+/- 2.3 %) / 2.86 ACH50 � 56.4 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 32.6 (+/- 16.7 %) Exponent (n) = 0.881 ( +/- 0.046 ) Correlation Coefficient = 0.99862 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 47.1 CFM 0.13 ACH Winter: 68.7 CFM Summer: 50.4 CFM 0.19 ACH 0.14 ACH Pau I Digitally signed bye,.Paul Higman D,IVcCN = Paul Higman C = US igma-;:. Dafe: 2016.05.06 b726:19-06'00' V GS Seryzes BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit B - BDma Building Information Volume 21489 Surface Area FloorArea--- 2223 Height 9 # of Bedrooms 2 # of Occupants Year of Construction 2015 Mind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas �Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost II Cooling SEER Location Climate Information VentilationWeather Factor I Energy Climate Factor Heating Degree Days Cooling Degree Days Design Winter Wind Speed Design Summer Wind Speed Design Winter Temp Diff Design Summer Temp Diff Equipment Information 0.87 .-.1-7.00 6128 297 7.3 mph 9.4 mph 73 deg F 15 deg F Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (11 0\/) Default Micr omanometer Energy Conservatory DG70 0 19028-7 y• G S "es BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit B - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (AOF) Altitude (ft) 70.0 57.0 _ 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.0 n/a n/a -60.5 -59.4 38.1 -55.3 -54.2 33.9 -49.2 -48.1 27.5 -43.0 -41.9 210.4 -36.9 -35.8 157.8 -31.0 -29.9 116.9 -25.1 -24.0 77.9 -19.1 -18.0 42.7 -1.2 n/a n/a Time Averaging Period: 10 None 1121 1162 -2.7 Ring A 1060 1099 -0.2 Ring A 957 992 0.1 Ring A 859 890 1.5 Ring B 745 772 1.1 Ring B 642 666 2.1 Ring B 525 544 1.3 Ring B 390 404 -3.0 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters @rVI& BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit B - BDma �omments House WRT Garage = detached BUILDING LEAKAGE TEST GS Services Ltd erv'^ ~'J' 2000 S. College Ave #308 Fort Collins, CO 80525 Email: Building Performance@GSServices.com Website: GSServices.co_m_ . Date of Test: 5/2/2016 Test File: Landmark - 3839 Precision Dr. - Merlot - Unit C - BDma Customer: Landmark Homes Technician: Project Number: Building Address: 3839 Precision Dr. Fort Collins., CO Test Results 1. Airflow at 50 Pascals: 1007 CFM50 (+/- 3.5 %) (50 Pa = 0.2 w.c.) 2.81 ACH50 2. Leakage Area: 55.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 30.9 (+/- 25.6 %) Exponent (n) = 0.890 (+/- 0.071 ) Correlation Coefficient = 0.99685 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 46.2 CFM 0.13 ACH 2. Estimated Design Infiltration Rate: Winter: 67.5 CFM Summer: 49.5 CFM 0.19 ACH 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman DNCN = Paul Higman C Higman:- us_ >� Date. 2016.05.06 07:41: :'51--06'00'