Loading...
HomeMy WebLinkAbout321 Urban Prairie St - Disclosures/Final Energy - 03/27/2016GnergyLogic analysis. Insight. answers. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: March 27, 2016 Rating No.: 37953 Building Name: Philgreen Construction Inc Rating Org.: EnergyLogic, Inc. Owner's Name: Philgreen Construction Inc Phone No.: 1.800.315.0459 Property: 321 Urban Prairie Way #1 Rater's Name: Brad Smith Address: Fort Collins, CO 80524 Rater's No.: 8809000 Builder's Name: Philgreen Construction Inc Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 321 Urban Prairie Way 1 Philgreen REM.blg Rating Date: 3/23'/16 Annual Energy Cost ($) __ _ 2012 IECC As Designed Heating: — 638 -- — 303 Cooling: 86 42 Water Heating: 121 109 SubTotal - Used to Determine Compliance: — — 846 454 Lights &Appliances: 422 413 Photovoltaics: -0 Service Charge: -640 — ------ 60 60 Total: _- -- -- 1328 287 '`— Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 20.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.290 Home Infiltration (Section 402.4.1.2): Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the re uirements by 46.3%. Name: Brad Smith 2016.03.27 Signature: �,� -- - - - �- U29-44_ O&G L Organization: EnergyLogic, Inc. — — Date: March 27, 2016 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Philgreen Construction Inc Design energy cost is based on the following systems: GSHP: Htg: 36.1 kBtuh, 3.9 COP. Clg: 27.5 kBtuh, 20.6 EER, with Desuperheater. Water Heating: Heat pump, Elec, 2.45 EF. Window -to -Floor Area Ratio: 0.23 Blower door test Htg: 633 Clg: 633 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. Page 2 Af/[/W Philgreen Construction Inc 321 Urban Prairie Way#1 Fort Collins, CO 80524 AL 0nergyL0 g C � _- r J LJ w�vw.anarpylopto,corn 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient r 1 Star I 1 Star Plus 2 Stars_T2 Stars Plus r3 Stars F3 Stars Plus 4 Stars 4 Stars PWs 5 stars 5 S�L..u� 500 401 400 301 300 251� 250 201 200 151 154101 100-91 90 86 BS71�70HERS Index: .Generallydormation -- - ---- ; Conditioned Area: -1427 sq. ft. -- -- HouseType. Tovmhouse, end unit — --� Conditioned Volume: 15144 cubic ft. Foundation: Slab Bedrooms: 2 Mechanical Systems Features Ground -source heat pump: Electric, Htg: 3.9 COP. Clg: 20.6 EER, w/DSH. Water Heating: Heat pump, Electric, 2.45 EF, 60.0 Gal. Duct Leakage to Outside: 10.00 CFM25. Ventilation System: Exhaust Only: 94 cfm, 15.0 watts. Programmable Thermostat Heating: Yes Cooling:Yes �BuildingShellFeatures--__—_�---__------.----_--..____ Ceiling Flat NA Slab: R-10.0 Edge, R-0.0 Under Sealed Attic: R-50.0 Exposed Floor. R-50.4 Vaulted Ceiling: NA Window Type: U-Value: 0.290, SHGC: 0220 Above Grade Walls: R-23.0 Infiltration Rate: Htg: 633 Clg: 633 CFM50 Foundation Walls: NA Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 _ —Range/Oven Fuel: Electric Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 600.00 Clothes Dryer EF: 3.01 Dishwasher (kWh/yr): 270.00 Calling Fan (chMatt): 0.00 The Home Energy Rating Standard Disclosure for thla home Is avallable from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software 04.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. Registry ID: 209568209 Rating Number: 37953 Certified Energy Rater. Brad Smith Rating Date: 3/23/16 Rating Ordered For. Philgreen Construction Inc Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 9.6 $279 113% Cooling 0.8 $24 10% Hot Water 3.9 $115 46% Lights/Appliances 14.0 $410 165% Photovoltaics -21.8 $-640 -258% Service Charges $60 24% Total 6.4 $248 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 3 Home 2012 International Energy Conservation Code Home Energy Rating Provider'- EnergyLogic, Inc.' % P.O. Box N . °. Berthoud, C080513 Phone # 1-800-315-0459 �jF No.He98-06g) l- w www.nrglo ic.com 2016.03.27Tv'tvy`SaoA i I 1 n.Jn.1 1 n­n.� 2012 IECC Certificate 321 Urban Prairie Way #1, Fort Collins, CO 80524 Building Envelope Insulation Ceiling: Above Grade Walls: Foundation Walls: Exposed Floor: Slab: Infiltration: Duct Total Duct Leakage: R-50.0 R-23.0 NA R-50.4 R-10.0 Edge, R-0.0 Under Htg: 633 Clg: 633 CFM50 Uninsulated 53.00 CFM @ 25 Pascals Window Data ^U-Factor SHGC— Window: 0.290 0.220 Mechanical GSHP: Electric, Htg: 3.9 COP. Cig: 20.6 EER, w/DSH. DHW: Heat pump, Electric, 2.45 EF, 50.0 Gal. Builder or Design Profession Signature REMNRate - Residential Energy Analysis and Rating Software 04.6.1