Loading...
HomeMy WebLinkAbout5803 Northern Lights Dr - Disclosures/Blower Door Test - 02/04/2016nergyLagic ona►ysis.. : insight.. .answers'. vm-w..nrglogic com Date of Test: 2/4/2016 Customer: Ryland Homes Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve BUILDING LEAKAGE TEST EneregyLogic, Inc PO Box N 309 Mountain Ave Berthoud, CO 80513 Phone: 800.319.0459 Fax: 970.532.5074 Website: www.nrglogic.com Test File: 5803 Northern Lights Dr -Multi Point Tectite Technician: Justin Heldenbrand Project Number: EnergyLogic (39573) Building Address: 5803 Northern Lights Dr Fort Collins, CO 80528 1336 CFM50 (+/- 0.5 %) 2.05 ACH50 73.5 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 103.8 (+/- 7.7 %) Exponent (n) = 0.653 ( +/- 0.020 ) Correlation Coefficient = 0.99952 4. Test Settings: Test Standard: RES NET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate 77.9 CFM 0.12 ACH 15.6 CFM per person Winter: 146.6 CFM Summer: 92.0 CFM 0.23 ACH 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 79.2 CFM Base Rate: 79.2 CFM Infiltration Credit: <0.0 CFM> Qnergyl;c)gic veyvv uglogic..com ' BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/4/2016 Test File: 5803 Northern Lights Dr -Multi Point Tectite Volume Surface Area Floor Area Height # of Bedrooms #—of Occupants Building Information 39062 7758 4173 20 --- _—_ 4 Year of Construction 2016 Wind Shield _ M� Heating and Cooling Cost and Efficiency Information Heating Fuel Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Gas Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days _ 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number ! Custom Calibration Date! Fan i Energy Conservatory Model 3 (110V) 1-- 6/1/2115 _ J Qneir L��gic Wymp.iglogic.com . BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/4/2016 Test File: 5803 Northern Lights Dr -Multi Point Tectite Depressurization Test: Environmental Data j Indoor_ Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 71.0 25.0 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -5.0 n/a n/a -64.3 -59.6 77.8 -60.7 -56.0 70.7 -57.5 -52.7 64.3 -52.6 -47.9 56.4 -48.9 -44.2 51.3 -44.8 -40.1 45.2 -40.9 -36.2 39.4 -37.0 -32.2 33.8 -4.5 n/a n/a Time Averaging Period: 0 None 1588 1509 0.7 Ring A 1516 1441 0.1 Ring A 1448 1376 -0.6 Ring A 1358 1291 -0.6 Ring A 1297 1232 -0.1 Ring A 1219 1158 0.1 Ring A 1140 1083 0.1 Ring A 1058 1006 0.2 Ring A Deviations from Standard RESNET Multi -Point Test - Test Parameters QnergyLc)gic ivM.M910gic.com BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/4/2016 Test File: 5803 Northern Lights Dr -Multi Point Tectite Comments Connection to: Mechanicals -50pa Garage -49.1 pa