Loading...
HomeMy WebLinkAbout1021 Linden Gate Ct - Disclosures/Final Energy - 02/17/2016(DnergyLogic analysis. Insight. answers. 2012 1ECCANNUAL ENERGY COST COMPLIANCE Date: February 17, 2016 Rating No.: 39217 Building Name: Bluestone Homes Rating Org.: EnergyLogic Inc. Owner's Name: Bluestone Homes Phone No.: 970.532.3220 or 800.315.0459 Property: 1021 Linden Gate Ct Unit B Rater's Name: Brad Smith Address: Ft Collins, CO 80524 Rater's No.: 8809000 Builder's Name: Bluestone Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1021 Linden Gate CtApt Bluestone Homes REM. Rating Date: 2/16/16 Annual Energy Cost ($) 2012 IECC As Designed Heating: 219 213 Cooling: 72 54 Water Heating: 86 48 SubTotal - Used to Determine Compliance: 377 315 Lights &Appliances: 362 358 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 979 913 ` Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.190 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES / This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 16.4%. 2016.02.17 Name: Brad Smith _ Signature: D—fit-�- 91(1�m _ Organization: EnergyLogic Inc. Date: February17, 2016 REM/Rate - Residential Energy Analysis and Rating Software 04.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Bluestone Homes Page 2 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 38.0 kBtuh, 92.1 AFUE. Water Heating: Instant water heater, Gas, 0.97 EF. Cooling:Air conditioner, 18.0 kBtuh,13.0 SEER. Window-to-FloorArea Ratio: 0.15 Blower door test: Htg:536 Clg:536 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect currentfederal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. ���, � Registry ID: 005427307 ��,/����� � , � RatingNumber: 39217 'I .... � � Y� I "�' o � � Bluestone Homes Certified Energy Rater: Brad Smith :�•;; � � Rating Date: 2/16l16 1021 Linden Gate Ct Unit B Rating Ordered For: Bluestone Homes ,, .. ' ='�'� Ft Collins,CO 80524 1 , -��- .--,I`-- ��f��-- -� ' � Estimated Annual Energy Cost �n�rr��rLoc�ic �,����� ��I��I�; � ,. , , .., „ .. , �/ � �� �/�\'� ��V `-' Confirmed �:r�n1RnarP�yi�,qac,can 5 �tars Plus � Use MMBtu Cost Percent Confirrned j Heating 29.7 �u197 22% � Cooling 1.1 $32 4% Uniform Energy Rating System Energy Efficient ,—.. HotWater 8.8 $53 6% �1 Star 1 Star Plus i 2 Stars 2 Stars Plus 3 Stars , 3 Stars Plus r4 Stars 4 Stars Plus 5 Stars 5 Stars Plus � Lights/Appliances 12.1 �355 41% i 500-401 400-301—f 300-25�50-201 � 200-151 � 150-101 � �00-91 90-86 85-71 70 or Less I i Photovoltaics -0.0 $-0 -0% HERS Index: 57 Service Charges $240 27% Generallnformation Total 51.7 5876 100% _ - - ConditionedArea: 871 sq.ft. HouseType: Duplex,singleunit Conditioned Volume: 10725 cubic ft. Foundation: More than one type p - - � Bedrooms: 1 � This home meets or exceeds the minimum Mechanical Systems Features AR 3 + criteria for all of the following: _ . __ . . _ _.. . _. EPAENERGYST Version Home Heating: Fuel-fired airdistribution,Natural gas,92.1 AFUE. 2012 International Energy Conservation Code Water Heating: Instant water heater,Natural gas,0.97 EF,0.0 Gal. Caoling: Air conditioner,Electric,13.0 SEER. Duct Leakage to Outside: 27.00 CFM25. Ventilation System: Exhaust Only:44 cfm,15.0 watts. Programmable Thermostat: Heating:Yes Cooling:Yes I . _.. _ _ . _. Building Shell Features ' _.. _ _. . .. .. Ceiling Flat: R-38.0 Siab: R-10.0 Edge,R-0.0 Under SealedAttic: NA Exposed Floor: R-42.0 Vaulted Ceiling: NA Window Type: U-Value:0.190,SHGC:0.240 Above Grade Walls: R-20.0 Infiltration Rate: H�q:536 Clg:536 CFM50 d Foundation Walls: NA Method: Blowerdoortest ' _ . _ . . .. _. _ . _ . . . . Lights and Appliance Features � Home Energy Rating Provider ,r�M-�;T``" �::.. . .._ _ _... "` . o �� . Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric Ener Lo ic,inc. .::=''r''y�:.��o'�• 9Y 9 .: o G'::. Percent Exterior Lighting: 100.00 Clothes Dryer Fuel: Electric P.O.Box N �;`zp �' _ ����_� ,. ., a�,�°`�; Refrigerator(kWh/yr): 645.00 Clothes Dryer EF: 3.01 Berthoud,CO 80513 '�'```�� - Dishwasher(kWh/yr): 270.00 Ceiling Fan(cfmlWatt): 0.00 Phone#1-800-315-0459 f;x wo:i��s-osr`. ��� The Home Energy Rating Standard Disclosure for this home is available from the rating provider. www.nrglogic.com �"��s � �-`4'(��jY=�� ��g;'� 2016.02.17 .�;.4� — t' `� A'\ REfH1lRate-Residential Energy Analysis and Rating Software v14.6.1 `'';.�Reo�T�T!o`';'`' This information does not constitute any warranty of energy cost or savings. 1�� � ' ` O 1985-2015 Noresco,Boulder,Colorado. - __I 1�;,28:�}4_�7��______.___ ertified Energy Rater � rt � � �� I, � gi � analysis. Insight. answers. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: February 17,2016 Rating No.: 39217 Building Name: Bluestone Homes Rating Org.: EnergyLogic Inc. Owner's Name: Bluestone Homes Phone No.: 970.532.3220 or 800.315.0459 Property: 1021 Linden Gate Ct ✓ Rater's Name: Brad Smith Address: Ft Collins,CO 80524 Rater's No.: 8809000 Builders Name: Bluestone Homes Weather Site: Ft.Collins,CO Rating Type: Confirmed File Name: 1021 Linden Gate Ct Bluestone Homes REM.bIg Rating Date: 2/16/16 Mnual Energy Cost($) 2072 IECC As Designed Heating: 636 481 Cooling: 260 145 Water Heating: 151 100 SubTotal-Used to Determine Compliance 1047 726 ✓ Lights&Appliances: 1075 1058 Photovoltaics: -0 -0 Service Charge: 480 480 Total: 2601 2264 ' Window U-Factor Check(Section 402.5) I Window U-Factor(Design must be equal or lower): 0.480 0.171 Home infiltration(Section 402.4.1.2): P�ISSES Duct Leakage(Section 4032.2): PASSES Mechanical Ventilation(Section 403.5): PASSES �-- -- -�- - — � i This home t�1EETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact,this home surpasses the re uirements by 30.6%. 2016.02.17 Name: Brad Smith Signature: ti�l -- -- --.�_1�0�1�QZ0� OrganizaGon: EnergyLogic Inc. Date: February 17,2016 — -- ----------� 'Design energy cost is based on the foilowing systems: Heating:Fuei-fired air distribution,75.0 kBtuh,92.1 AFUE. Water Heating:Instant water heater,Gas,0.97 EF. Cooling:Air conditioner,17.6 kBtuh,13.0 SEER. REMIRate-Residential Energy Malysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. O 1985-2015 Noresco,Boulder,Colorado. 1 IECCANNUAL ENERGY COST COMPLIANCE 20 2 Bluestone Homes Page 2 Window-to-FloorArea Ratio:0.16 Blower door test:Htg:1489 CIg:1489 CFM50 In accordance with IECC,building inputs,such as setpoints,infiltration rates,and window shading may have been changed prior to calculating annual energy cost. Furthermore,the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subjectto change,and software updates should be obtained periodically to ensure the compliance calculations reflect currentfederal minimum standards. REM/Rate-Residential Energy Malysis and Rating Software v14.6.1 � This informaUon does not constitute any warranty of energy cost or savings. I O 1985-2015 Noresco,Boulder,Colorado. � � , � Registry ID: 268097412 - �„/Q,M�,�� , � Rating Number: 39217 � f/arod , Bluestone Homes Certified Energy Rater: Brad Smith :',.��4'� � � j Rating Date: 2/16l16 [,::�=�'- 1021 Linden Gate Ct Rating Ordered For: Bluestone Homes ..,..,, . ,..•> '•.�-' ' Ft Collins,CO 80524 ' _�`�___. �����- .��' 1 .. � _ . _. . _ _ ���r �.�� g� ` Cl ��� � �7,` �L Estimated Mnual Energy Cost �. � �� <..�l �' �`� >.•\��� Confirmed .. , ,.:,> ,. , � / //' . � � i ���'r��t'�Y��fl'�"��� 5 �tBffS ��US Use MMBtu Cost Percent Confirmed � Heating 71.2 $465 22% - � Cooling 0 $0 0% Uniform Energy Rating System Energy Efficient o Hot Water 18.2 $109 5/o 1 Star 1 Star Plus 2 Stars r2 Stars Plus 3 Stars 3 Stars Plus 4 Stars I 4 Stars Plus � 5 Stars 5 Stars Plus LightslAppliances 40.1 $1058 50% 500-401 400-301 300-251 � 250-201 200-151 150-101 � 100-91 90-86 I 85-71 _ 70 or Less - Photovoltaics -0.0 $-0 -0% HERS Index: � I Service Charges $480 23% _ ... _ . Generallnformation Total 131.6 52112 100% _.. _ . . .. . . . Conditioned Area: 4621 sq.ft. HouseType: Duplex,whole building - - - - Conditioned Volume: 48773 cubic ft. Foundation: More than one type .... .. .. ... . . . . ... Bedrooms: 2 This home meets or exceeds the minimum . _. . _. _ .... .._ . ... ,. Mechanical Systems Features. . _. ._ ion cri eria or a o e o owmg: EPA ENERGY STAR Vers' 3 Home Heating: Fuel-fired air distribution,Natural gas,92.1 AFUE. 2012 International Energy Conservation Code Water Heating: Instantwater heater,Natural gas,0.97 EF,0.0 Gal. Duct Leakage to Outside: 0.00 CFM25. � Ventilation System: Exhaust Only:69 cfm,15.0 watts. Programmable Thermostat: Heating:Yes Cooling:Yes .... . ... .... .... _ _ . ._ , ... . . . . ... . . .... ... . . .. Building Shell Features - � _. ._ . .. ... . _ .. .. .. ..._ _ . . _ .. Ceiling Flat: R-49.0 Slab: R-0.0 Edge,R-0.0 Under Sealed Attic: NA Exposed Floor: R-42.0 Vaulted Ceiling: R-49.0 Window Type: U-Value:0.170,SHGC:0.290 Above Grade Walls: R-20.0 Infiltration Rate: Htg:1489 Clg:1489 CFM50 � _. Foundation Walls: R-19.0 Method: Blowerdoortest .. _ . _ . .... .. . .... .. ..... .. . .. . . �. ..._. _ _. ; _.... . _... .._.. .... ... .._.__ ... _ . .. . ..... Lights and Appliance Features � Home Energy Rating Provider •�=°�'T`'`"`'� , . -- .. _ ...... _ ... .... ...... .... .. .. ...._. ..,. "" OF1 Gq6 '" Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas Ener Lo ic,Inc. �:���ryM= h�~o��Y. � 9Y 9� ;, o �`.-�'�•:. � .::. ��:.-._':.:.::;;;:::... �,�,�, Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric P.O.Box N ;'=Q -� ..::.r.;:;,,�;;;:. m,�;�: Refrigerator(kWh/yr): 691.00 Clothes Dryer EF: 3.01 � Berthoud,CO 80513 '' ^ - '` '' ........ '; Dishwasher(kWh/yr): 270.00 Ceiling Fan(cfmNVatt): 70.40 Phone#1-500-315-0459 ��'x s'rio�i���aoa�; ��� ,-,c� � __._.. �. ,,.A', _ _;.K, q ;; The Home Energy Rating Standard Disclosure for this home is available from the rating provider. www.nrglo ic.com '��q '��';;f-;j'�:i w�;;:' 2016.02.17 -�, BeD,T„z�� � '' REM/Rate-Residential Energy Analysis and Rating Software v14.6.1 � .� �`` + `' "`� I ,.,.�,:, This information does not constitute any warranfy of energy cost or savings. � ��'�i 10:03:42-�7���� O 1985-2015 Noresco,Boulder,Colorado. Certified Energy Rater