Loading...
HomeMy WebLinkAbout4926 Corsica Dr - Disclosures/Blower Door Test - 02/01/2016.;. r. BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 -- Fort Collins, CO 80525 Email: Building Perform ance@GSServices.com Website: GSServices.com Date of Test: 2/1 /2016 Customer: Luxury Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: Test File: Luxury - 4926 Corsica Dr. - BD1 Technician: Project Number: Building Address: 4926 Corsica Dr. / Fort Collins, CO 80525 1418 CFM50 (+/- 2.7 %) 1.99 ACH50 78.0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 90.3 (+/- 19.5 %) Exponent (n) = 0.704 ( +/- 0.054 ) Correlation Coefficient = 0.99709 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 70.9 CFM 0.10ACH 2. Estimated Design Infiltration Rate: Winter: 129.2 CFM Summer: 85.7 CFM 0.18 AC H 0.12 AC H Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Digitally signed by: Paul Hi rn CN = Paul Higman C = US Higman... a}eo2010.02.0215:14:34- GS S�ivice.s ,- 77- : BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/1/2016 Test File: Luxury - 4926 Corsica Dr. - BD1 Building Information Volume Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction Wind Shield Location Climate Information Ventilation Weather Factor 0.87 42751 Energy Climate Factor 17.00 4310 12 Heating Degree Days Cooling Degree Days 6128 297 5 1 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph 2015 Design Winter Temp Diff Design Summer Temp Diff 73 deg F 15 deg F IV ...... . ... Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER . . . . . . ............ . . ..... .. .. ...... . ...... . . ........ .... . .. .. .... ..... .. ......... .............. . .. ...... ... . ..... ... .. . ..... .... ..... . ...... . ........... ........ Equipment Information I Type Manufacturer Model Serial Number Custom Calibration Date. .. .. ... . . . ... . _..............._.__......_..- Fan Energy Conservatory Model 3(11OV) Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 . . ..... . ... ...... ..... ....... .. .. .... . . .. . ... .. .... ... ....... .. ...... .. ........... . .. ... . ... ..... ...... . . ...... . .. ............. ... .. ... ... ....... .. . ................ .. ... .. . .... BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/1/2016 Test File: Luxury - 4926 Corsica Dr. - BD1 Depressurization Test: Environmental Data . ...... ... -.... ...... ........ ................ _.... .. Indoor Temperature (A°F) Outdoor Temperature (A°F) 28.0 .. Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -3.6 n/a n/a -62.9 -59.5 91.4 -57.9 -54.5 79.1 -52.0 -48.7 61.3 -45.6 -42.2 49.1 -40.0 -36.6 44.4 -33.5 -30.2 33.2 -28.0 -24.7 236.5 -21.4 -18.1 148.8 -3.1 n/a n/a Time Averaging Period: 0 None Altitude (ft) 5000.0 Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1718 1642 2.4 Ring A 1602 1530 1.5 Ring A 1414 1351 -2.9 Ring A 1269 1212 -3.7 Ring A 1209 1155 1.4 Ring A 1048 1002 0.8 Ring A 910 870 0.9 Ring B 724 691 -0.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters '-Seuces BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/1/2016 Test File: Luxury - 4926 Corsica Dr. - BD1 j Comments House WRT Garage = -47.3 pa