Loading...
HomeMy WebLinkAbout826 Jerome St - Disclosures/Blower Door Test - 08/10/2018BUILDING LEAKAGE TEST Date of Test: 8/10/2018 Customer: Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Test File: 826 Jerome St Unit 2 2.06ACH 8.10.18 Technician: Greydon Studer EnergyLogicv Project Number: Building Address: 826 Jerome St Unit 2 Fort Collins, CO 80524 561 CFM50 (+/- 1.2 %) 2.06 ACH50 30.9 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 30.0 (+/- 14.9 %) Exponent (n) = 0.749 ( +/- 0.039 ) Correlation Coefficient = 0.99867 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: You created this PDF from an application that is not licensed to print to novaPDF printer (hftp://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/10/2018 Test File: 826 Jerome St Unit 2 2.06ACH 8.10.18 Building Information Location Climate Information Volume 16335 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction 2018 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 You created this PDF from an application that is not licensed to print to novaPDF printer (hftp://www.novapdf.com) ' BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/10/2018 Test File: 826 Jerome St Unit 2 2.06ACH 8.10.18 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 70.0 85.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.5 n/a n/a -72.0 -69.3 123.6 660 714 -0.4 Ring B -66.0 -63.4 108.6 619 670 -0.0 Ring B -60.0 -57.4 96.5 584 632 1.6 Ring B -54.0 -51.4 75.5 517 559 -2.3 Ring B -48.0 -45.4 66.6 486 526 0.8 Ring B -42.0 -39.4 54.3 439 475 1.3 Ring B -36.0 -33.4 40.6 380 411 -0.8 Ring B -30.0 -27.4 30.5 330 357 -0.1 Ring B -2.8 n/a n/a Time Averaging Period: 5 Deviations from Standard RESNET Multi -Point Test - Test Parameters - The Time Averaging Period is less than 10 seconds. You created this PDF from an application that is not licensed to print to novaPDF printer (hftp://www.novapdf,c ) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/10/2018 Test File: 826 Jerome St Unit 2 2.06ACH 8.10.18 Comments No attached garage. CAZ -49 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)