HomeMy WebLinkAbout3308 Buteos Ct - Special Inspections/Engineering - 07/06/2005lsF�;k_ SOIEOGIC July 6, 2005 Savant Homes, Inc. `� �� 3201 East Mulberry Street, Suite B ' �- Fort Collins, Colorado 80524 330 31/ Attn: Mr. Mark Teplitsky Re: Foundation Footing and Wall Steel Observation Lot 37, Hearthfire Phase II Fort Collins, Colorado Soilogic Project # 05-3010 Mr. Teplitsky: Soilogic, Inc. personnel have completed the foundation footing and wall steel observation you requested for the referenced project. The results of those observations are included with this report. On June 29, 2005, Soilogic personnel observed the strip footing and interior column pad dimensions and reinforcing steel placed for the interior column pads for the referenced residence. he strip footings were measured at approximately 12, 16, 18 and 20 inches in width. The interior column pads were measured at approximately 18, 20, 22 and 24 inches square. The reinforcing steel placed for the interior column pads consisted of #5 bars spaced at approximately 12 inches on center in both directions. At the time of our site visit, the strip footing and column pad widths and placed reinforcing steel observed appeared to be in general compliance with the construction plans. (Advanced Engineering, l_LC #1008-05.01B dated May 2, 2005) On July 6, 2005, Soilogic personnel observed the reinforcing steel placed for the foundation walls and counter -forts for the referenced residence. The reinforcing steel placed for the garage stem -walls consisted of two #5 bars placed continuously at the top and bottom of the walls. The reinforcing steel placed for the baseman walls consisted of two #5 bars placed continuously at the top, middle and hottenr of the walls with one #5 bar placed midway between the top and middle run and between the middle and bottom run. The reinforcing steel placed for the counter -forts consisted of #5 bars placed at 12 Soilogic, Inc. 1435 Hilltop Circle • Windsor, CO 80550 • (970)674-3430 Lot 37 — Ilearthfire Phase II Soilogic # 05-3010 inches on center in both directions. The reinforcing steel placed for the basement window penetrations consisted of two #5 bars placed at the top, bottom and sides of the window frame with diagonal bars placed at each of the four (4) window corners. The lap lengths, spacing and coverage distances observed appeared to meet minimum requirements. At the time of our site visit, the reinforcing steel observed appeared to have been placed in general compliance with the construction plans. (Advanced Engineering, LLC #1008-05.01B dated May 2, 2005) If you have any questions concerning this report or if we can assist you in any other way, please do not hesitate to contact us. We appreciate the opportunity to be of service to you on this project. Very truly yours, Soilogic, Inc. p0 REG�S d„o V ON rF V: • �SS�ONAL r Wolf von Carlowi , P.E. Principal Engineer