Loading...
HomeMy WebLinkAbout1015 Andrews Peak Dr - Disclosures/Final Energy - 09/26/2005Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 09/26/05 (970)377-1056 CUSTOMER: BLS Development 1015 Andrews Peak Dr. 101 Fort Collins Co BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 55 F Volume = 21090 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 3 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 83 1589 -1.2 Ring A 51 75 1511 -0.1 Ring A 44 67 1429 2.5 Ring A 40 58 1331 0.7 Ring A 34 46 1187 -1.8 Ring A 22 29 944 -0.5 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9953 C = 170.98 n = 0.554 Results: Air Flow @ 50 Pascals : 1496 CFM50 +/- 0.8% = 4.26 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 104.55 Square Inches +/- 6.4% Equivalent Leakage Area (CANADA) = 180.00 Square Inches +/- 4.0% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 110 CFM = 36.7 CFM/OCCUPANT = 0.31 AIR CHANGES PER HOUR