May 18, 1994
Curtis Zook
Front Range Roasters
11091 N. Wolff Way
Westminster, CO 80030
Dear Mr. Zook:
1525 Blue Spruce Drive
Fort Collins, Colorado 80524-2004
General Health 498-6700
Environmental Health 498-6775
FAX 498-6772
The plans and specifications submitted for the construction of Kenny
Rogers Roasters, 3460 South College Avenue, Fort Collins, Colorado, have
been reviewed by this department. The following items were not clearly
specified in the plans or were not in compliance with the Rules and
Regulations Governing the Sanitation of Food Service Establishments in the
State of Colorado. These items must be clearly specified in writing or be
modified to be in compliance with the above regulations prior to approval
of the submitted plans. The plans are not approved at this time. All
plans must be approved prior to commencement of construction.
1) All food service equipment must be NSF (National Sanitation
Foundation) approved or its equivalent. Custom made equipment and
- used equipment ca^.net hc- �,prove`7,. tin Y_il-it-is. Visually inspected. The
following equipment is not approved at this time due to lack of
information and/or lack of NSF approval. Submit make and model
numbers and specification sheets on the following equipment:
a) The submitted plans do not show the location for the dipper well
(01), yogurt machine (#35), under counter refrigerator (#51),,
and dough mixer (#65). Provide information indicating where
this equipment will be located or if it will be used.
b) The Rotisserie unit (#33) is not NSF listed, Please provide
additional specification sheets so this unit can be evaluated'.
c) The Rotisserie unit (#40; Hardt KR-D1) is not NSF approved. For
this oven to be approved for use, the following must be
addressed:
Courtlyn W. Hotchkiss
District I
BOARD OF COUNTY COMMISSIONERS
Janet Duvall
District II
Jim Disney
District III
Mr. Zook
May 18, 1994
Page 2
1) The exterior brick surface is not approved. Brick finishes
are not smooth and easily cleanable. All exterior surfaces
must be smooth, durable, non -absorbent, light in color and
easily cleanable. This also includes the wood storage
areas.
2) Access must be provided for cleaning the interior of the
rotisserie, including the floor under the rotisserie.
3) The rotisserie's water pan must be drained to sewer through
an approved air gap. Also, an approved, properly installed
back°flow prevention device rrsa--be provided -on the water
supply line to the rotisserie.
4) Please be advised, wood burning appliances may require air
quality permits. To determine if a permit ,is required,
please submit projected amount of wood that will be burned
in the rotisserie.
5) The rotisserie will require visual inspection before it can
be approved.
2) The Convection oven (#9) and Rotisserie' Unit (#33) must be installed
in such a way as to permit easy cleaning around this equipment. It
is recommended that gas lines be long enough to allow the equipment
to be pulled far away from the wall for cleaning or to install pop -off
valves on the gas lines to allow the equipment to be completely
disconnected from the gas lines and the wall. Heavy equipment such
as the convection oven, rotisserie unit (#33), chicken warmer (#6),
open top refrigerators, etc. should also be mounted on casters to
allow for easy mobility.
-3-)- Be advised--that--no--appurtenances; such _as_syrup__lines, carbonators,
drop -in cold plates, drain lines or bottle holders are permitted in
potable ice bins or ice machines or any unit used to store potable
ice.
4) The kitchen exhaust hoods must be NSF (National Sanitation Foundation)
approved or its equivalent; must be constructed of stainless steel;
must overhang all cooking equipment not less than 6 inches beyond the
edge of the cooking surface on all open sides.
Be advised, make up air must be filtered, tempered during winter
months and mechanically introduced into the establishment at a volume
equal to or greater than what is being exhausted; must be distributed
so as not to short circuit the exhaust systems.
a) The exhaust hood switch(es) must be interlocked with the makeup
air system so the hood(s) can not operate without adequate make-
up air.
b) Submit specification sheets with UL Test data for the air flows
for the exhaust hoods.
Mr. Zook
May 18, 1994
Page 3
c) Provide information indicating the volume of outside air RTU-1
& 2 will provide into the building.
d) Sheets CA 1-4 of the submitted plans indicate only one MUA will .
be provided to supply air to the exhaust hood. Sheet M-1-3 show
two MUA units. Please clarify what will be provided.
5) Submit the size dimensions (length, width, and depth) of the 3-
compartment sink basins so the adequacy of the proposed water heater
can be determined. Also, sheet M-2 indicated an AO Smith BTC-305
water heater will be installed and submitted cut sheets indicate a
Paloma - water heater=will bc- provided--- Sheet- M-2 shows - the water
heater will be installed in the office, sheet EQ-1 indicates the water
heater to be in the chicken prep area. Please clarify what water
heater is to be proposed and where it will be located.
6) Because of the high potential for contamination, the mop sink needs
to be relocated out, away from the middle of the kitchen. Please
provide information indicating where this sink will be located.
Provide mop hangers or hooks around the mop sink to hang and air dry
mops.
7) To help prevent cross contamination of the clean utensils, dishes, and
pots and pans from being soiled, it is recommended that the dishwasher
disposal and pre rinse area be relocated to the west side of the
dishwasher and the clean dish drainboard to the east side of the
dishwasher. It is also recommended that the dishwashers drainboards
and the 3-compartment sink and its drainboards be fabricated in one
piece so the 3-compartment sink and its drainboards can be utilized
as an additional drainboard space.
8) Submit a proposed menu.
9) Hand sinks must be easily accessible in all rooms where food is
prepared or utensils are washed. The hand sink located in the back
kitchen area is not easily accessible to the dishmachine area. An
additional hand sink must be provided in this area. Provide
information on a proposed location for this hand sink. (The.
Department recommends a small goose neck faucet, equipped with hot and
cold water and separately plumbed be provided at the pre rinse sink
(#15) to be used for hand washing.) Be advised, an additional hand
sink will be required at the west end of the service area when the
"future char -broiler" is provided and installed.
10) All drain lines from equipment such as: vegetable sinks,
dishmachines, ice- machines, ice bins, drink, dispensers, drink overflow
drains, refrigeration/freezer units not equipped with evaporation
pans, steam kettles, walk-in compressors and cold tables holding ice
must be directed to a floor drain or floor sink and be properly air
gaped.
Mr. Zook
May 18, 1994
Page 4
Submit a complete plumbing schedule indicating all floor drains and
floor sinks and how the above listed equipment is to be drained.
a) Submit information indicating where the walk-in condenser units
will drain.
b) The sink in.prep table (#17) must have an indirect drain.
Provide information on how this will be done.
c) The dishwasher (#22) must have an indirect drain/air gap
upstream from the trench drain. Provide information on how this
--wil--1—be done: =_._ __ ._ ..- _ --__._ _ _ ._
_ q - _'
11) Be advised, floor sinks must not be installed under equipment or
cabinetry where they cannot be cleaned. All floor sinks and floor
drains must be installed so that they are flush with the finished
floor.. ,
12) All plumbing and electrical conduit are to be installed within and
behind walls or below floors. Exposed water pipes, sewer lines, or
electrical conduit running along walls or floors are not approved.
13) Be advised that all exit and restroom doors must be fitted with self -
closures. The carry out window must also be self -closing or must be
provided with a screen.
14) Be advised, 30 foot candles of light are required on all working
surfaces and 20 foot-candles of light on all other surfaces and
equipment in the kitchen, storage areas, service counter, bus station,
restrooms, utensil washing area, and all food prep areas. At least
10 foot candles of light must be provided in all areas of the walk-in
- cooler. -All lights in -the above areas, excluding the restrooms must
be shielded in an approved manner. Be advised, all lights inside
equipment must also be shielded.
15) Floors, walls, ceilings, counter tops, storage shelves, cabinets and
all work surfaces located within the kitchen, storage areas,
restrooms, bus station, serving area, dishwashing area, walk-in, and
all food prep areas must be of an approved material that is smooth,
easily cleanable, nonabsorbent and of a light color.
Submit information on'the finishes to be used:
a) North wall in service area #103
b) Ceiling finish above service area #103
c) Wall and ceiling finish in walk,in cooler (#107)
16) All floor/wall junctures and stationary equipment floor junctures in
the kitchen, storage areas, restrooms, bus station, serving .area,
dishwashing area, walk-in, and all food prep areas must be provided.
with approved concave coving.
Mr. Zook
May 18, 1994
Page 5
17) All equipment, cabinets, and counters that are not easily moveable
must be: a) spaced so that floors, walls, and exterior surfaces of
equipment can be, easily cleaned; or b) be sealed to adjoining
walls, equipment, cabinets, or counters. Hard to clean areas, spaces
or gaps are not approved.
18) Be advised that the lowest shelf of all storage shelves located in all
kitchen areas, storage areas, and the walk-in must be situated at
least six inches up off the floor.
19) Please be advised solid metal shelving in the walk-in cooler and-
- - - ---freezer--is--not-approved; -unless-NSF--approved-for-use--in walk-ins-. -
wooden shelves, pallets, or any wooden interior finishes are not
permitted in the walk-in cooler.
20) The outside dumpster storage area must be located on or above a smooth
surface of nonabsorbent material such as concrete or asphalt. Submit
this information.
21) Toxic materials and surplus cleaning items must be stored away from
food operations, food storage and utensil washing facilities. Submit
a proposed location.
The plans are not approved at this time. Once items #la-c, 4b-d, 5,
6, 7, 8, 9, 10a-c, 15a-c, 20 and 21 have been submitted in writing, the
plans will be reviewed for final approval. After the last item is
resubmitted, the department will review the plans and resubmittals within
10 days.
Be advised that Colorado Revised Statutes (1989) 12-44-206 require
plans and specifications be submitted to the local health department and
approved prior to beginning construction.
Please feel free to contact this department i-f questions arise; or if
I can be of further service at 498-6775.