Loading...
HomeMy WebLinkAbout3421 Meadowlark Ave - Miscellaneous - 08/14/2001SARA'S ENERGY SCORING 1225 W Prospect P-14 DATE FT. COLLINS CO 80526 08/14/01 (970)495-9922 CUSTOMER: Kaufman and Broad, 3421 Meadowlark lVe. FT. COLLINS CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 17876 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By Data Points: House Pressure Fan Pressure CFM $Error Fan Configuration 57 280 971 1.1 Ring B 50 245 907 -0.5 Ring B 41 210 839 -0.5 Ring B 33 174 763 -1.5 Ring B 24 140 683 0.0 Ring B 18 115 619 1.4 Ring B Correlation Coefficient Flow Coefficient Exponent r = .3979 C = 195.65 n = 0.193- Results Air Flow @ 50 Pascals : 912 CFM50 +/- 0.6% 3.06 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 95.70 Square Inches +/- 2.9$ Equivalent Leakage Area (CANADA) = 142.17 Square Inches +/- 1.8% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 67 CFM = 33.6 CFM/OCCUPANIr = 0.23 AIR CHANGES PER HOUR u Z�-