HomeMy WebLinkAbout309 Snowy Owl Cir - Miscellaneous - 10/30/1998Fort Collins residential energy code 7/96
Air sealing disclosure form
Job address: 309 Snowy Owl Circle
General contractor: Sherman Homes, INc
Air sealing contractor: Collins Cashway Lumber Co
A. Prescriptive path
Ml e certify that the air sealing -rP-gtirements specifie&in the -current -City of Fort Collins Residential -EnergyCode
-
have been completed in this building, in accordance with the "Air Sealing Checklist" published by the City of Fort Collins.
Certified by: Phone:
Business firm: Date:
Address: Signature:
B. Performance path
IlWe certify that this building has met the air leakage performance threshold specified in the current
City of Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures," published
by the City of Fort Collins.
Testing contractor: Richmond Assoc.
Date of test: 10-29-98
CFM50: 460 +/-0 .4ro Air flow through the blower door at 50 Pascals pressure difference (cfm)
Volume: 13,500 Volume of home (cu. ft.)
ACH50: 2.04 Air change rate per hour at 50 Pascals pressure difference
ACH50 = (CFM50 x 60) / Volume
The performance threshold for code compliance is ACH50
not exceeding 5.0 ac/h
Certified by: Peter Sherman Phone: 221-0 77
Business firm: Sherman Homes Date: 0 x98
Address:4535 Eagle Lake Dr. Signature:`
Ft. collins, CO 4
Instructions
Complete either Part A or Part B.
Part A is to be signed by the air sealing contractor or representative of the general contractor.
Part B is to be signed by the blower door testing contractor or representative of the general contractor.
The "Blower Door Test Report" or equivalent documentation must be attached.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
s sdse.sb 1/5527 — 6R496
309 SNOWY OWL CIRCLE FT. COLLINSP CO
PROWHITE III° an Fiberglas
Guardian Fiberglass, Inc.
lWO East North Street • Albion, MI.492224-
Insulation Certificate
Meets Requirements of Federal Specification 1111-1-1030B. Type 1 Class A and ASTM C-764, Type I Category I
APPLICATION CIIARI'
BAGS PER
1000 SQ. FT.
MAXIMUM
NET COVERAGE
PEkt SQ, FT.,
rirlN><MltM
T"IC ' S5 `.
R-60
43.5
23.0 SF
1.307 LBS
20.50"
R-50
35.2
28.4 SF
1.057 LBS
17.50"
R-44
31.0
32.3 SF
0.928 LBS
15.75"
R-38
26.7
37.4 SF
0.803 LBS
14.00"
R-30
20.2
49.5 SF
0.606 LBS
11.00"
R-26
18.2
54.8 SF
0.547 LBS
10.001,
R-22
15.0
136.5 SF
0.45i LBS
8.5-0"
R-19
13.1
76A SF
0.394 LBS
7.50'1
R-13
9.3
107.5 SP
0.279 LBS
5.50"
R-11
7.9
126.6 SF
1 0.237 LBS
1 4.75"
I -OR PNEU MA'I K APPLICATION ONLY
INSULATION SHOULD NOT BE INSTALLED OITR ISAVL' NIS S
THERMAL RESISTANCE VALUES ARIL DE I ERMINED IN ACCORDANCE. WITH ASTM C-687 AND ASI1VI C-91 S
NET COVFRAGF. INCLUDES FRAMING
Builder's and Applicator's Certification Signature
This is to certify the insulation has been installed in conformance with the requirements indicated on this card
to provide thermal resistance value of R 3 using bags of insulation to cover 13 ov square feet area.
Depth of previous insulation , R 1-1 Upgrade
I9ch� R-'Aw
Type of insulation: V-a it New Construction
Mm al Sherman Homes, Inc.c F221-0777
Date Cym my Nome 3uildcrl Address • I' Ione Builder's Signature
1r? Itl "I `��r; sI�t4,a ci U6.e)"C_L�Y j n..... ,..,._. ��.. �I. �:__.....__
Richmond Associates
420 Oak St.
DATE Ft. Collins Co 80521
10/29/98 ( 970 } 224-3140
CUSTOMER: Pete Sherman
309 Snowy Owl
Ft. Collins CO
BUILDING CONDITIONS :
Interior Temp = 68 F Exterior Temp = 50 F
Volume = 13500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft.
Number of Stories = 1 Number of Occupants = 2
wina s�nieia ractor = �
HOUSE TEST : Depressurized
Fan Model = 3
Performed By SARA
Data Points :
House Pressure Fan Pressure CFM gError Fan Configuration
53 67 473 0 .4 Ring B
44 57 436 -0 . 2 Ring B
35 48 399 0 . 3 Ring B
29 40 364 -1 . 3 Ring B
23 34 335 -0 . 1 Ring B
13 22 269 0 . 9 Ring B
Correlation Coefficient Flow Coefficient Exponent
r = . 9993 C = 94 . 30 n = 0 . 405
Results : _ _ __ _ _ _
Air Flow @ 50 Pascals :
= 460 CFM50 +/- 0 . 4�
�- = 2 . 04 ACH50 (Air Changes Per Hour)
��i.:i-:u .-.
Effective Leakage Area (LBL) - 46 . 87 Square Inches +/- 1 . 7$
Equivalent Leakage Area (CANADA) = 70 . 37 Square Inches +/- 1 . 0$
Estimated Natural Infiltration {50 Pascal Flow Divided By 17 . 0)
= 27 CFM
= 13 . 5 CFM/OCCUPAN2'
= 0 . 12 AIR CHANGES PER HOUR
� Fort Collins residential energy code 7/96
Meclianical s sterns disclosure form
Job address: 309 Snowy Owi Circle
General contractor: Sherman Homes , INc.
Mechanical contractor: 1 son ea ing
_ _. _ _ _ _
Space heating system :`, ;
Input capacity AFUE or
Location Fuel I Tvpe I Manufacturer I Model# I kBtuh or kW HSPF
Bsmt gas F.A. Amana UID070Ca4 70K AFUE
_ _ _
Space cooling system ; ` ` '
� � � � � Input capacitv I_
Location I Fuel I Type � Manufacturer � Model# � kBtuli or kW � SEER
N/A
Water heating system `: -
input capacify Energy Storage
Location Fuel I Type I Manufacturer I Model# I kBtuh or kW I Factor I volume
Bsmt Gas A 0 Smith FSG50 36kBtuh 268 50ga1
__ _. __ _. __ __
� Certification ': ' ` ` ` -
I1We certify ttiat tfie above-listed equipment was instailed in the buiiding at the above locations in conformance with the
current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code,and that it was installed in
accordance witli manufacturer's instructions. INVe cerGry that any ductwork has been installed in conformance with
the current requirements of tlie City of Fort Collins Residential Energy Code and Mechanical Code.
Certified by: Peter Sherman Phon • 21- 7
Business firm: Sherman Homes Da e: 1 - 98
Address:4535 Eagie Lake Dr.giynature:
Ft . Collins , 80524
Instructions
_. , . >: . - ;,> ; .
This disclosure form is to be signed by the mechanical contractor or representative of the general contractor.
Please type or print, except(or the signature.
If there are multiple systems serving any function, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer. ,�,�nu,<.w�rss��-sa�9e