Loading...
HomeMy WebLinkAbout321 Urban Prairie St - Disclosures/Blower Door Test - 03/02/2015(DnergyLogic analysis. insight. answers. www.nrglogic.com BUILDING LEAKAGE TEST EnergyLogic Inc. PO Box N 309 Mountain Ave. Berthoud, CO 80513 Phone: (800) 319-0459 Fax: (970) 532-5074 Email: tyler.stein@nrglogic.com Website: www.nrglogic.com Date of Test: 3/2/2015 Test File: 321 Urban Prairie Wy - Philgreen - MP Tectite Customer: Philgreen Construction Technician: Tyler Stein - EnergyLogic Inc. Project Number: 37956 Building Address: Unit 4 321 Urban Prairie Wy Fort Collins, Co 80524 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates 565 CFM50 (+/-1.5 %) 2.63 ACH50 31.1 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 35.1 ( +/- 25.3 %) Exponent (n) := 0.710 ( +/- 0.066 ) Correlation Coefficient = 0.99565 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 37.2 CFM 0.17 ACH 12.4 CFM per person 2. Estimated Design Infiltration Rate: Winter: 62.0 CFM Summer: 38.9 CFM 0.29 ACH 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 29.3 CFM Base Rate: 35.2 CFM Infiltration Credit: <5.9 CFM> QnergyLogic maraglogic.com BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/2/2015 Test File: 321 Urban Prairie Wy - Philgreen - MP Tectite Building Information Volume 12901 Surface Area 2123 Floor Area 1271 Height _ _ j # of Bedrooms 30 2 # of Occupants 3 _ Year of Construction — 2016 M , Wind Shield Heating and Cooling Cost and Efficiency Information Heating Fuel Heating Fuel Cost Gas Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87� Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days _ 297_ _ 7.3 mph Design Winter Wind Speed Design Summer Wind Speed Design Winter Temp Diff 9.4 mph 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Fan Energy Conservatory Model Model 3 (110V) Serial Number Custom Calibration Date Default 12830-7 �_ 3/22/2013 Micromanometer Energy Conservatory DG700 QnergyLogic ,ww:nrglogic,com BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/2/2015 Test File: 321 Urban Prairie Wy - Philgreen - MP Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 63.0 54.0 5000.0 _ Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 0.1 n/a n/a -58.4 -58.5 111.7 -56.5 -56.6 102.6 -51.8 -51.8 89.9 -47.9 -47.9 83.6 -43.6 -43.6 71.8 -39.6 -39.7 66.7 -36.0 -36.0 53.2 -31.8 -31.8 45.4 0.1 n/a n/a Time Averaging Period: 10 None 628 637 0.9 Ring B 602 611 -1.0 Ring B 564 572 -1.3 Ring B 544 552 0.6 Ring B 504 512 -0.2 Ring B 486 493 2.9 Ring B 435 441 -1.5 Ring B 402 408 -0.4 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters QnergyLogic www.mglogic.com BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/2/2015 Test File: 321 Urban Prairie Wy - Philgreen - MP Tectite Comments Connections to: Garage = -49.2 Pa Mechanicals = NA (all electric)