HomeMy WebLinkAbout5764 Northern Lights Dr - Disclosures/Blower Door Test - 03/07/2015I • J BUILDING LEAKAGE TEST (DnergyLogic EnergyLogic Inc. analysts. Insight. answers. PO Box N 309 Mountain Ave. Vi1WW.YlY(JiQt1C.C4IC1 Berthoud, CO 80513 Phone: (800) 319-0459 Fax: (970) 532-5074 �-'Email: iyler.stein@nrglogic.com Website: www.nrglogic.com Date of Test: 3/7/2015 Customer: Ryland Homes Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Test File: 5764 Northern Lights Dr - Ryland - MP Tectite Technician: Tyler Stein - EnergyLogic Inc. Project Number: 38277 Building Address: 5764 Northern Lights Fort Collins, CO 80528 1385 CFM50 (+/- 1.4 %) 2.46 ACH50 76.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 115.5 ( +/- 23.9 %) Exponent (n) = 0.635 ( +/- 0.063 ) Correlation Coefficient = 0.99516 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 80.8 CFM 0.14 ACH 20.2 CFM per person Winter: 151.9 CFM Summer: 95.3 CFM 0.27 ACH 0.17 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 61.5 CFM Base Rate: 65.9 CFM Infiltration Credit: <4.5 CFM> VA%nergyLogic ,,� ... 1"". -111. . ..... 1. mwarglogic.com BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/7/2015 Test File: 5764 Northern Lights Dr - Ryland - MP Tectite Building Information Vol wne_ Area 33755 8323 -Surface. Floor Area 3594 Height # of Bedrooms 20 # of Occupants Year of Construction Wind Shield —3 4 2016.-.. M- Heating and Cooling Cost and Efficiency Information Heating Fuel Gas 'Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 1 Energy Climate Factor Heating Degree Days — Cooling Degree Days Design Winter Wind Speed Design Summer Wind Speed Design Winter Temp Diff Design Summer Temp Diff Equipment Information Type Manufacturer Fan Energy Conservatory -Micromanometer Energy Conservatory Model Serial Number Model 3 (110V) DG700 12830-7 0.87 17. 0 0 6128 .-297--_ 7.3 mph 9.4 mph 73 deg F 15 deg F Custom Calibration Date Default 3/22/2013 (DnergyLogic vrrr1.nrglogi..c.com BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/7/2015 Test File: 5764 Northern Lights Dr - Ryland - MP Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) l Outdoor Temperature (OF) 68.0 45.0 Data Points Altitude (ft) 5000.0 Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.9 n/a n/a -63.8 -60.9 81.0 1620 1599 1.8 Ring A -58.9 -56.1 67.5 1483 1463 -1.8 Ring A -53.5 -50.6 61.3 1414 1395 -0.1 Ring A -50.3 -47.4 55.6 1349 1331 -0.6 Ring A -47.1 -44.2 52.2 1308 1291 0.7 Ring A -43.1 -40.2 45.6 1225 1208 0.2 Ring A -38.4 -35.5 37.3 1110 1095 -1.8 Ring A -35.3 -32.4 35.5 1083 1069 1.5 Ring A -2.9 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None ' (nergyLogic vmnorgtogic.com BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/7/2015 Test File: 5764 Northern Lights Dr - Ryland - MP Tectite Comments Connections to: Garage = -45.8 Pa Mechanicais = -50