Loading...
HomeMy WebLinkAbout4915 Corsica Dr - Disclosures/Final Energy - 10/05/20152012 IECC Energy Cost Compliance S p c Property Organization Luxury Homes of NC GS Services Ltd 4915 Corsica Dr (970)490-1612 Fort Collins, CO 80526 Paul Higman Weather:Ft. Collins, CO Builder Luxury Homes of NC 4915 Corsica Luxury Homes of NC Dr -Clary plan -Confirmed. big Annual Energy Cost $/yr 2012 IECC As Designed .:., ........... ;:Heating:.483 Cooling:.. 185. .. ;137' Water Heating . :.: 179 113 :,_. •,: - ::;:., ::: ;; :.......:.::..:..._.....................::.... .::......... ...... ... 1'SubTotal=` UseiJto Deter'mine.:Compliance ::. ... - . , 847 . Lights Et Appliances 1014 100,1 Photovoltaics -0 0 . Service Charge .. 240 240.. fTotal',:••:„:,....; :.:E:;;:.:..:...,..... ,. :. ... , :... ..,..201:,7 ....:.....:.... ..:......:....... ... Mandatory Requirements ......... Annual'Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U: Va(ue..andSH6`C:Gheck (per; Section 402:5.) ... .. PASSES: Home Infiltration (Section 402.4,1.2) PASSES:.: Duct Leakage (Section 403.2.2) PASSES. Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1).... PASSES Mandatory Requi.rements:Check Box: (IECC 12:). PASSES: This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 8.3%. Digitally signed Paul by: Paul Higman DX.jCN = Paul Name i Paul Higman Signature g Higfnan C = us H 171 a n�D e: 2015.10.05 Organization I GS Services Ltd Date i 5 October 2015 ' 1 :44:24-06'00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.6.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2015 Noresco, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 4915 Corsica Dr, Fort Collins, CO by Luxury Homes of NC exceeds the minimum requirements for the 2012 International Energy Conservation Code Building Features Ceiling Flat.l.NA Duct : NA ,.... . n Sealed Attic:.R i NA i Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Vaulted Ceilig-38.0�Total Duct Leakage: 172.00 CFM C 25 Pascals Above.:Grade Walls ! R-26.0. Infiltration: Htg: 1662 C.lg: 1662 CFM50 Foundation Wallstlk-l5.0 Window: U-Value: 0.330;.5HGC: 0.310 Exposed Floor! NA. Heating .Fuel -fired air distribution; Natural gas, 92.1 4FUE. !. SlabjR 0 0 Edge,.R 0.0 Under Cooling. Air conditioner, Electric, 13.0 SEER. I I Water.Fieating Instant water heater, Na.tural.gas, 0.88.EF, 0.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 513 and with all mandatory requirements. Name Paul Higman Signature Digitally sighed by: Paul Hlgrnan ....... --— .................... -- ...... -- — .......................... Organization GS 5ervices: Ltd. Date October.05, 2015 The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Design - Residential Energy Analysis Software 04.6.1 City of Fort Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type Stock Plan Permit — Projected Worst -Case Rating Builder Model: 1 Lot -specific Permit - Projected Rating Completed Home — Confirmed Rating 2. Data Required for All SPA Ratings Builder: Luxury Homes of Northern Colorado Energy Rater: Paul Higman Address: Address: 4915 Corsica Dr Rating Firm: GS Services Date: 10-4-15 Duct Location Inputs (REM/Rate "Duct Systems" page) Duct Location Su ply Return % Area R-Value % Area R-Value All within Conditioned space 100 r-0 100 r-0 Thermal Envelope Clarification Component Thermal Location Crawl space El N/A ❑ Inside ❑ Outside Attic ❑ N/A ❑ Inside ® Outside Bonus room ® N/A ❑ Inside ❑ Outside Ductwork adjacent to garage ® N/A ❑ Inside ❑ Outside Other: ❑ N/A ❑ Inside ❑ Outside Utility Rates Energy Service Variable Source Charge Rate Electricity 5 $/mo 0.1 $/kWh Natural 15 $/mo 0.6 $/therm as 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration Front elevation Foundation orientation type(s) Options included E Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑ Attach REM/Rate Energy Code Inspection Checklist 3113. Additional Information for Lot -Specific Permit — Projected Rating i 1 Attach REM/Rate 2012 IECC Energy Cost Compliance report showing `PASS" u Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) p Attach REM/Rate Home Energy Rating Certificate Updated 03/01/2014