Loading...
HomeMy WebLinkAbout863 Campfire Dr - Disclosures/Blower Door Test - 09/14/2015BUILDING LEAKAGE TEST Date of Test: 9/14/2015 Test File: 863 Campfire Dr Multi Point Tectite Blank Technician: Brad Smith - EnergyLogic Project Number: 37820 Customer: Hawkstone Builders, LLC Building Address: 863 Campfire Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1071 CFM50 ( +/- 1.5 %) (50 Pa = 0.2 w.c.) 2.56 ACH50 2. Leakage Area: 58.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 57.3 ( +/- 40.7 %) Exponent (n) = 0.748 ( +/- 0.102 ) Correlation Coefficient = 0.99076 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 62.5 CFM 0.15 ACH 15.6 CFM per person 2. Estimated Design Infiltration Rate: Winter: 117.5 CFM 0.28 ACH Summer: 73.7 CFM 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 51.4 CFM Base Rate: 56.3 CFM Infiltration Credit: <4.9 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/14/2015 Test File: 863 Campfire Dr Multi Point Tectite Blank Building Information Volume 25139 Surface Area 5391 Floor Area 2631 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2015 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 13013-7 4/16/2015 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/14/2015 Test File: 863 Campfire Dr Multi Point Tectite Blank Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 78.0 84.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.4 n/a n/a -69.0 -66.2 46.2 1233 1321 -0.0 Ring A -65.3 -62.5 41.4 1167 1251 -1.2 Ring A -60.5 -57.7 38.3 1125 1205 1.1 Ring A -56.9 -54.1 33.8 1057 1133 -0.3 Ring A -53.0 -50.2 31.1 1015 1088 1.2 Ring A -49.8 -47.0 28.7 976 1046 2.3 Ring A -48.5 -45.7 25.0 914 979 -2.2 Ring A -48.8 -45.9 247.2 931 997 -0.8 Ring B -5.3 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/14/2015 Test File: 863 Campfire Dr Multi Point Tectite Blank Comments Connection to: Garage: -46.8 Mechanicals: -50 Pa