HomeMy WebLinkAbout2808 Sunset View Dr - Disclosures/Blower Door Test - 08/25/2015BUILDING LEAKAGE TEST Date of Test: 8/25/2015 Test File: Toll Brothers Blower Door Customer: Toll Brothers 10 Inverness E Dr Ste 125 Englewood, CO 80112 Phone 303-708-0730 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates Technician: Jay Bundy Building Address: 2808 Sunset View Fort Collins, Colorado 80528 1301 CFM (+/ 0.3 %) 1.55 ACH 0.31 CFM per ft2 floor area 120.1 in2 ( +/- 3.4 %) Canadian EgLA @ 10 Pa 59.9 in2 (+/ 5.2 %) LBL ELA @ 4 Pa 0.12 CFM50 per ft2 surface area Flow Coefficient (C) = 77.9 ( +/- 8.0 %) Exponent (n) = 0.720 ( +/- 0.020 ) Correlation Coefficient = 0.99886 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door 1. Estimated Average Annual Infiltration Rate: 73.2 CFM 0.09 ACH 2. Estimated Design Infiltration Rate: Winter: 75.8 CFM 0.09 ACH Summer: 45.1 CFM 0.05 ACH 3. Recommended Whole Building Mechanical 71.4 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: No Text No Text