Loading...
HomeMy WebLinkAbout5603 Scarlet Ibis - Disclosures/Final Energy - 08/31/20152012 IECC Energy Cost Compliance Property Organization Spanjer Homes GS Services Ltd 5603 Scarlet Ibis (970) 449-1612 Fort Collins, CO 80525 Paul Higman Weather:Ft. Collins, CO Builder Spanjer Homes - 5603 Scarlet Spanjer Homes Ibsis - Confirmed.blg Annual Energy Cost Cooling Water Heating SubTotal - Used to Determine Compliance Lights Ft Appliances Photovoltaics Service Charge Total Mandatory Requirements Annual Energy Cost Check I Duct Insulation R-Value Check (per Section 405.2) 'Window U-Value and SHGC Check (per Section 402.5) Home Infiltration (Section 402.4.1.2) Duct Leakage (Section 403.2.2) ;Mechanical Ventilation (Section 403.6) -Mechanical Ventilation Fan Efficacy (Section 403.6.1) iMandatory Requirements Check Box (IECC 12) S rtcu $/yr 2012 IECC As Designed 407 429 105 103. 109 66j 621 598' 781 7801. -0 -0 240 240 1642 1618 PASSES PASSES PASSES; PASSES PASSES, PASSES' PASSES' -- —...-- -- - -PASSES; This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 3.7%. Digitally signed Paul by;P.aulHigman DN:.CN = Paul Name Paul Hi man Signature Hi an C = US g g H I g CTl a n Da e: 2015.08.31 Organization GS Services Ltd Date 31 August 2015 09:57:53-06'00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.6.1 This information does not constitute any warranty of energy cost or savings. 1985-2015 Noresco, Boulder, Colorado. of F�`o`rt` Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type I. Stock Plan Permit— Projected Worst -Case Rating ❑ Lot -specific Permit - Projected Rating 1, Completed Home — Confirmed Rating Builder Model: Address: Address: 5603 Scarlet Ibis 2. Data Required for All SPA Ratings Builder: Spanier Homes Rating Firm: Energy Rater: Paul Higman GS Services Date: 8-28-15 Duct Location Inputs (REM/Rate "Duct Systems' page) Duct Location Supply Return % Area R-Value % Area R-Value All within Conditioned space 100 r-0 100 r-0 Thermal Envelope Clarification Component Thermal Location Crawl space II N/A ❑ Inside ❑ Outside Attic ❑ N/A ❑ Inside ® Outside Bonus room ® N/A ❑ Inside ❑ Outside Ductwork adjacent to garage M N/A ❑ Inside ❑ Outside Other: ❑ N/A El Inside [I Outside Utility Rates Energy Service Variable Source Charge Rate Electricity 5 $/mo 0.1 $/kWh Natural 15 $/mo 0.6 $/therm gas 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration Front elevation Foundation orientation type(s) Options included Attach REM/Rate 20121ECC Energy Cost Compliance report showing 'PASS" Attach REM/Rate Energy Code Inspection Checklist 313. Additional Information for Lot -Specific Permit — Projected Rating J Attach REM/Rate 2012 IECC Energy Cost Compliance report showing 'PASS' ❑ Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate 20121ECC Energy Cost Compliance report showing 'PASS' (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) L Attach REM/Rate Home Energy Rating Certificate Updated 03/01/2014