HomeMy WebLinkAbout5603 Scarlet Ibis - Disclosures/Final Energy - 08/31/20152012 IECC Energy Cost Compliance
Property
Organization
Spanjer Homes
GS Services Ltd
5603 Scarlet Ibis
(970) 449-1612
Fort Collins, CO 80525
Paul Higman
Weather:Ft. Collins, CO Builder
Spanjer Homes - 5603 Scarlet Spanjer Homes
Ibsis - Confirmed.blg
Annual Energy Cost
Cooling
Water Heating
SubTotal - Used to Determine Compliance
Lights Ft Appliances
Photovoltaics
Service Charge
Total
Mandatory Requirements
Annual Energy Cost Check
I Duct Insulation R-Value Check (per Section 405.2)
'Window U-Value and SHGC Check (per Section 402.5)
Home Infiltration (Section 402.4.1.2)
Duct Leakage (Section 403.2.2)
;Mechanical Ventilation (Section 403.6)
-Mechanical Ventilation Fan Efficacy (Section 403.6.1)
iMandatory Requirements Check Box (IECC 12)
S rtcu
$/yr
2012 IECC
As Designed
407
429
105
103.
109
66j
621
598'
781
7801.
-0
-0
240
240
1642
1618
PASSES
PASSES
PASSES;
PASSES
PASSES,
PASSES'
PASSES'
-- —...-- -- - -PASSES;
This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 3.7%. Digitally signed
Paul by;P.aulHigman
DN:.CN = Paul
Name Paul Hi man Signature Hi an C = US
g g H I g CTl a n Da e: 2015.08.31
Organization GS Services Ltd Date 31 August 2015 09:57:53-06'00'
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.6.1
This information does not constitute any warranty of energy cost or savings.
1985-2015 Noresco, Boulder, Colorado.
of
F�`o`rt` Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction
SPA Guide
1. Submittal and Rating Type
I. Stock Plan Permit— Projected Worst -Case Rating
❑ Lot -specific Permit - Projected Rating
1, Completed Home — Confirmed Rating
Builder Model:
Address:
Address: 5603 Scarlet Ibis
2. Data Required for All SPA Ratings
Builder: Spanier Homes Rating Firm:
Energy Rater: Paul Higman
GS Services
Date: 8-28-15
Duct Location Inputs (REM/Rate "Duct Systems' page)
Duct Location
Supply
Return
% Area
R-Value
% Area
R-Value
All within Conditioned space
100
r-0
100
r-0
Thermal Envelope Clarification
Component
Thermal Location
Crawl space
II N/A
❑ Inside
❑ Outside
Attic
❑ N/A
❑ Inside
® Outside
Bonus room
® N/A
❑ Inside
❑ Outside
Ductwork adjacent to garage
M N/A
❑ Inside
❑ Outside
Other:
❑ N/A
El Inside
[I Outside
Utility Rates
Energy
Service
Variable
Source
Charge
Rate
Electricity
5 $/mo
0.1 $/kWh
Natural
15 $/mo
0.6 $/therm
gas
3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating
Worst -Case Configuration
Front elevation
Foundation
orientation
type(s)
Options
included
Attach REM/Rate 20121ECC Energy Cost Compliance report showing 'PASS"
Attach REM/Rate Energy Code Inspection Checklist
313. Additional Information for Lot -Specific Permit — Projected Rating
J Attach REM/Rate 2012 IECC Energy Cost Compliance report showing 'PASS'
❑ Attach REM/Rate Energy Code Inspection Checklist
3C. Additional Information for Completed Home — Confirmed Rating
❑ Attach REM/Rate 20121ECC Energy Cost Compliance report showing 'PASS'
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
L Attach REM/Rate Home Energy Rating Certificate
Updated 03/01/2014