HomeMy WebLinkAbout326 Osiander St - Disclosures/Blower Door Test - 09/11/2015 (2)0 BUILDING LEAKAGE TEST Date of Test: 9/11/2015 Test File: 326 Osiander St —Unit B - Philgreen - MP Tectite Customer: Philgreen Construction Technician: Brad Smith - EnergyLogic Inc. Project Number. 37066 Building Address: Unit B 326 Osiander St Test Results 1. Airflow at 50 Pascals: 650 CFM50 (+/- 2.9 %) (50 Pa = 0.2 w.c.) 3.00 ACH50 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level 35.8 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 12.6 (+/- 48.5 %) Exponent (n) = 1,008 ( +/- 0.127 ) Correlation Coefficient = 0.99218 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 37.9 CFM 0.18 ACH 9.5 CFM per person Winter. 71.3 CFM Summer: 44.8 CFM 0.33 ACH 0.21 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 39.1 CFM Base Rate: 44.0 CFM Infiltration Credit: <4.9 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/11/2015 Test File: 326 Osiander St —Unit B - Philgreen - MP Tectite Building Information Volume 12991 Surface Area 3507 Floor Area 1404 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory I Model 3 (110V) I IDefault BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/11/2015 Test File: 326 Osiander St_Unit B - Philgreen - MP Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) OutdoorTemperature (OF) Altitude (ft) 73.0 72.0 5003.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -4.4 n/a nla -66.4 -60.6 142.8 -62.7 -56,9 125.8 -58.4 -52.6 112.2 -54.1 -48.3 95.6 -50.7 -44.8 80.1 -47.3 -41.4 65.0 -43.7 -37.8 49.5 -36.9 -31.0 39.7 -7.3 n/a n/a Time Averaging Period: 0 Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 709 784 -0.6 Ring B 666 736 -0.5 Ring B 629 696 1.6 Ring B 581 643 2.4 Ring B 532 589 1.1 Ring B 480 531 -1.4 Ring B 419 464 -5.6 Ring B 376 416 3.3 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. BUILDING -LEAKAGE TEST Page 4 of 4 Date of Test: 9/11/2015 Test File: 326 Osiander St Unit B - Philgreen - MP Tectite Comments Connections to: Garage = - 47.013a Mechanicals = -50