Loading...
HomeMy WebLinkAbout326 Osiander St - Disclosures/Blower Door Test - 09/11/2015BUILDING LEAKAGE TEST Date of Test: 9/11/2015 Test File: 326 Osiander St Unit A- Philgreen - MP Tectite (2)(1) Customer: Philgreen Construction Technician: Brad Smith - EnergyLogic Inc. Project Number: Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Building Address: UnitA 326 Osiander St 593 CFM50 (+/- 2.3 %) 2.93 ACH50 32.6 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 26.2 (+/- 40.2 %) Exponent (n) = 0.797 ( +/- 0.105 ) Correlation Coefficient = 0.99143 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 34.6 CFM 0.17 ACH 11.5 CFM per person Winter: 65.0 CFM Summer: 40.8 CFM 0.32 ACH 0.20 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 30.9 CFM Base Rate: 35.3 CFM Infiltration Credit: <4.5 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/11/2015 Test File: 326 Osiander St —Unit A- Philgreen - MP Tactile (2)(1) Building Information Volume 12139 Surface Area 3284 Floor Area 1283 Height 20, . # of Bedrooms 2 # of Occupants 3 Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model ! Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) j Default Micromanometer Energy Conservatory DG700 13013-7 4/16/2015 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/11/2015 Test File: 326 Osiander St Unit A- Philgreen - MP Tectite (2)(1) Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 76.0 73.0 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -4.1 n/a n/a -65.7 -60.5 130.4 678 718 4.1 Ring B -63.9 -58.7 114.8 636 674 0.1 Ring B -58.6 -53.4 93.4 574 609 -2.6 Ring B -54.2 -49.0 83.4 543 575 -1.4 Ring B -49.7 -44.5 71.5 503 533 -1.3 Ring B -45.7 -40.5 60.5 463 491 -2.1 Ring B -41.9 -36.7 55.9 445 472 1.7 Ring B -38.2 -33.0 47.0 409 433 1.7 Ring B -6.3 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE -TEST. Page 4 of 4 ... Date of Test: 9/11/2015 Test File: 326 Osiander St —Unit A - Philgreen - MP Tectite (2)(1) Comments Connections to: Garage = -46.8 Pa Mechanicals = -50