Loading...
HomeMy WebLinkAbout5750 Crossview Dr - Disclosures/Blower Door Test - 08/06/2014BUILDING LEAKAGE TEST Date of Test: 08/06/2015 Technician: Jay Bundy Test File: Meritage Blower Door Customer: Meritage Homes 6892 S.Yosemite Court, Suite 1-201 Centennial, Colorado 80112 Phone 720-482-0202 Building Address: 5750 Crossview Drive Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 947 CFM ( +/- 0.4 %) (50 Pa = 0.2 w.c.) 0.94 ACH 0.19 CFM per ft2 floor area 2. Leakage Areas: 79.6 in2 ( +/- 4.1 %) Canadian EqLA @ 10 Pa 37.6 in2 ( +/- 6.3 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.09 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 45.2 ( +/- 9.7 %) Exponent (n) = 0.778 ( +/- 0.024 ) Correlation Coefficient = 0.99852 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 56.7 CFM 0.06 ACH 2. Estimated Design Infiltration Rate: Winter: 63.6 CFM 0.06 ACH Summer: 36.1 CFM 0.04 ACH 3. Recommended Whole Building Mechanical 87.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 08/06/2015 Test File: Meritage Blower Door Building Conditions Inside Temperature: 78 deg F Heating Fuel: Gas Outside Temperature: 64 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 60583 ft3 Ventilation Weather Factor: 0.87 Surface Area: 10984 ft2 Energy Climate Factor: 17.0 Floor Area: 4984 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT House @50PA = 47 BUILDING LEAKAGE TEST Page 3 Date of Test: 08/06/2015 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -3.0 n/a +/- 0.00 -65.0 372.4 1140 1125 0.5 Ring B -60.0 321.5 1060 1046 -0.3 Ring B -55.0 274.4 980 967 -1.0 Ring B -50.0 241.6 920 908 0.6 Ring B -45.0 201.1 840 829 0.2 Ring B