Loading...
HomeMy WebLinkAbout5750 Crossview Dr - Disclosures/Final Energy - 08/06/20152012 IECC ANNUAL ENERGY COST COMPLIANCE Date: August 06, 2015 Rating No.: 02071201 Building Name: Meritage5022 Full Rating Org.: Bugress-Inc. - BCCI Owner's Name: Meritage Homes Phone No.: 303-300-4527 Property: 5750 Crossview Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80528 Rater's No.: 7479033 Builder's Name: Meritage Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 5750 Crossview Drive.blg Rating Date: 08/06/2015 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2012 IECC As Designed Heating: 653 683 Cooling: 208 167 Water Heating: 116 116 SubTotal - Used to Determine Compliance: 977 967 Lights & Appliances: 886 953 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 2104 2159 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.310 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 1.1%. Name: Robert Hutchinson Signature: Organization: Bugress-Inc. - BCCI Date: August 06, 2015 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 60.0 kBtuh, 92.0 AFUE. Water Heating: Conventional, Gas, 0.67 EF. Cooling: Air conditioner, 29.6 kBtuh, 13.0 SEER. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Meritage5022 Full Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Window-to-Floor Area Ratio: 0.12 Blower door test: Htg: 920 Clg: 920 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 5750 Crossview Drive, Fort Collins, CO by Meritage exceeds the minimum requirements for the 2012 International Energy Conservation Code Building Features Ceiling Flat: NA Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Sealed Attic: R-21.0 Total Duct Leakage: 108.00 CFM @ 25 Pascals Vaulted Ceiling: NA Infiltration: Htg: 920 Clg: 920 CFM50 Above Grade Walls: R-15.0 Window: U-Value: 0.310, SHGC: 0.350 Foundation Walls: R-11.0 Heating Fuel-fired air distribution, Natural gas, 92.0 AFUE. Exposed Floor: R-21.0 Cooling N/A Slab: R-0.0 Edge, R-0.0 Under Water Heating Conventional, Natural gas, 0.67 EF, 50.0 Gal. Duct: NA 08/06/2015 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Name: Robert Hutchinson Signature: Organization: Bugress-Inc. - BCCI Date: August 06, 2015 The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 Meritage5022 Full 5750 Crossview Drive Fort Collins, CO 80528 5 Stars Plus Confirmed Registry ID: 272226074 Rating Number: 02071201 Certified Energy Rater: Robert Hutchinson Rating Date: 08/06/2015 Rating Ordered For: Meritage Homes Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 98.6 $637 33% Cooling 0 $0 0% Hot Water 19.5 $117 6% Lights/Appliances 35.2 $953 49% Photovoltaics -0.0 $-0 -0% Service Charges $240 12% Total 155.6 $1946 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 3 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code 2012 International Energy Conservation Code BurgessConstructionConsultantsInc 101 W Renner Rd, Suite 400 Richardson, Texas 75082 214-888-7260 214-888-7261 Uniform Energy Rating System 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less Energy Efficient HERS Index: 55 Efficient Home Comparison: 45% Better General Information Conditioned Area: 4984 sq. ft. HouseType: Single-family detached Conditioned Volume: 60583 cubic ft. Foundation: Conditioned basement Bedrooms: 4 Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.0 AFUE. Water Heating: Conventional, Natural gas, 0.67 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Air Cycler: 118 cfm, 150.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: NA Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: R-21.0 Exposed Floor: R-21.0 Vaulted Ceiling: NA Window Type: U-Value: 0.310, SHGC: 0.350 Above Grade Walls: R-15.0 Infiltration Rate: Htg: 920 Clg: 920 CFM50 Foundation Walls: R-11.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 475.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.83 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado.