Loading...
HomeMy WebLinkAbout3010 Des Moines Dr - Disclosures/Blower Door Test - 05/02/2015BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 Fort Collins, CO 80525 Date of Test: 5/2/2015 Test File: Savant - 3010 Des Moines - BDma Technician: Paul Higman Project Number: Customer: Savant Homes Timnath, CO 80547 Building Address: 3010 Des Moines Fort Collis, CO 80525 Test Results 1. Airflow at 50 Pascals: 1560 CFM50 ( +/- 1.2 %) (50 Pa = 0.2 w.c.) 2.99 ACH50 2. Leakage Area: 85.8 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 68.6 ( +/- 8.9 %) Exponent (n) = 0.799 ( +/- 0.025 ) Correlation Coefficient = 0.99952 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 73.9 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 104.6 CFM 0.20 ACH Summer: 76.7 CFM 0.15 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/2/2015 Test File: Savant - 3010 Des Moines - BDma Building Information Volume 31310 Surface Area Floor Area 3215 Height 10 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/2/2015 Test File: Savant - 3010 Des Moines - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 60.0 51.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.2 n/a n/a -60.2 -60.0 94.3 1745 1781 -1.3 Ring A -54.2 -54.0 80.8 1618 1651 -0.5 Ring A -47.9 -47.7 67.2 1479 1509 0.5 Ring A -41.9 -41.7 53.4 1322 1349 -0.0 Ring A -36.6 -36.4 43.9 1202 1227 1.3 Ring A -32.9 -32.7 36.7 1101 1123 1.1 Ring A -24.9 -24.7 217.3 873 891 0.3 Ring B -18.2 -18.0 126.2 667 681 -1.3 Ring B -0.2 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/2/2015 Test File: Savant - 3010 Des Moines - BDma Comments house wrt garage = -45.6 pa