Loading...
HomeMy WebLinkAbout5632 Kadenwood Dr - Disclosures/Blower Door Test - 02/20/2015BUILDING LEAKAGE TEST Date of Test: 2/20/2015 Technician: Michael Chavez Test File: Meritage Blower Door Customer: Meritage Homes 7400 E Orchard Rd Greenwood Village, Colorado 80111 Phone Building Address: 5632 Kadenwood Drive Fort Collins, Colorado 80525 Test Results 1. Airflow at 50 Pascals: 1242 CFM ( +/- 0.0 %) (50 Pa = 0.2 w.c.) 1.47 ACH 0.31 CFM per ft2 floor area 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 0.13 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 1080.8 ( +/- 0.5 %) Exponent (n) = 0.035 ( +/- 0.001 ) Correlation Coefficient = 0.99799 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 503.3 CFM 0.60 ACH 2. Estimated Design Infiltration Rate: Winter: 543.9 CFM 0.64 ACH Summer: 309.1 CFM 0.37 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 2/20/2015 Test File: Meritage Blower Door Building Conditions Inside Temperature: 71 deg F Heating Fuel: Gas Outside Temperature: 48 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 50655 ft3 Ventilation Weather Factor: 0.87 Surface Area: 9382 ft2 Energy Climate Factor: 17.0 Floor Area: 4016 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage with respect to House @50 PA= 45 BUILDING LEAKAGE TEST Page 3 Date of Test: 2/20/2015 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -9.3 n/a +/- 0.00 -65.0 49.6 1275 1247 0.0 Ring A -60.0 49.2 1270 1242 -0.0 Ring A -55.0 48.8 1265 1237 -0.0 Ring A -50.0 48.4 1260 1232 -0.0 Ring A -45.0 48.0 1255 1227 0.0 Ring A