HomeMy WebLinkAbout2951 Joseph Dr - Disclosures/Blower Door Test - 04/22/2015BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave Suite 308 Fort Collins, CO 80525 Date of Test: 4/22/2015 Test File: Savant Homes 2951 Joseph Dr -BD Technician: Paul Higman Project Number: Customer: Savant Homes Timnath, CO Building Address: 2951 Joseph Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1221 CFM50 ( +/- 1.2 %) (50 Pa = 0.2 w.c.) 2.54 ACH50 2. Leakage Area: 67.2 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 94.4 ( +/- 8.3 %) Exponent (n) = 0.654 ( +/- 0.023 ) Correlation Coefficient = 0.99937 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 57.9 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 81.9 CFM 0.17 ACH Summer: 60.0 CFM 0.12 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/22/2015 Test File: Savant Homes 2951 Joseph Dr -BD Building Information Volume 28890 Surface Area Floor Area 2483 Height 10 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/22/2015 Test File: Savant Homes 2951 Joseph Dr -BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 71.0 64.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.0 n/a n/a -60.2 -58.3 54.4 1334 1359 0.7 Ring A -55.1 -53.1 47.7 1251 1274 0.2 Ring A -50.0 -48.0 41.0 1162 1183 -0.5 Ring A -45.1 -43.1 36.2 1094 1114 0.5 Ring A -35.2 -33.3 25.2 917 934 -0.1 Ring A -30.6 -28.7 192.9 823 838 -1.2 Ring B -25.0 -23.1 144.8 714 727 -1.2 Ring B -20.0 -18.1 111.1 626 638 1.7 Ring B -1.9 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/22/2015 Test File: Savant Homes 2951 Joseph Dr -BD Comments House WRT Garage = -45.9 pa