HomeMy WebLinkAbout5709 Crossview Dr - Disclosures/Blower Door Test - 03/27/2015BUILDING LEAKAGE TEST Date of Test: 03/27/2015 Technician: Doug Groff Test File: Meritage Blower Door Customer: Meritage Homes 6892 S.Yosemite Court, Suite 1-201 Centennial, Colorado 80112 Phone 720-482-0202 Building Address: 5709 Crossview Drive Fort Collins, Colorado 80525 Test Results 1. Airflow at 50 Pascals: 1298 CFM ( +/- 0.1 %) (50 Pa = 0.2 w.c.) 1.26 ACH 0.24 CFM per ft2 floor area 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 0.12 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 901.2 ( +/- 1.5 %) Exponent (n) = 0.093 ( +/- 0.004 ) Correlation Coefficient = 0.99763 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 418.1 CFM 0.41 ACH 2. Estimated Design Infiltration Rate: Winter: 491.3 CFM 0.48 ACH Summer: 279.2 CFM 0.27 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 03/27/2015 Test File: Meritage Blower Door Building Conditions Inside Temperature: 70 deg F Heating Fuel: Gas Outside Temperature: 43 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 5.0 Volume: 61641 ft3 Ventilation Weather Factor: 0.87 Surface Area: 11144 ft2 Energy Climate Factor: 17.0 Floor Area: 5314 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage with respect to House @50 PA = 46 BUILDING LEAKAGE TEST Page 3 Date of Test: 03/27/2015 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -0.0 n/a +/- 0.00 -65.0 57.0 1365 1330 -0.0 Ring A -60.0 56.1 1355 1320 0.0 Ring A -55.0 55.3 1345 1310 0.1 Ring A -50.0 54.0 1330 1296 -0.2 Ring A -45.0 53.2 1320 1286 0.1 Ring A