HomeMy WebLinkAbout5614 Coppervein St - Disclosures/Blower Door Test - 03/23/2015BUILDING LEAKAGE TEST Date of Test: 3/23/2015 Technician: Doug Groff Test File: Meritage Blower Door Customer: Meritage Homes 7400 E Orchard Rd Greenwood Village, Colorado 80111 Phone Building Address: 5614 Coppervein Street Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 1381 CFM ( +/- 0.0 %) (50 Pa = 0.2 w.c.) 1.33 ACH 0.28 CFM per ft2 floor area 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 0.12 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 1154.8 ( +/- 1.3 %) Exponent (n) = 0.046 ( +/- 0.003 ) Correlation Coefficient = 0.99260 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 537.1 CFM 0.52 ACH 2. Estimated Design Infiltration Rate: Winter: 589.5 CFM 0.57 ACH Summer: 334.9 CFM 0.32 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3/23/2015 Test File: Meritage Blower Door Building Conditions Inside Temperature: 70 deg F Heating Fuel: Gas Outside Temperature: 52 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 62247 ft3 Ventilation Weather Factor: 0.87 Surface Area: 11101 ft2 Energy Climate Factor: 17.0 Floor Area: 5011 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT House @ 50 PA = 45.5 BUILDING LEAKAGE TEST Page 3 Date of Test: 3/23/2015 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -1.1 n/a +/- 0.00 -65.0 61.8 1420 1396 -0.0 Ring A -60.0 61.4 1415 1391 -0.0 Ring A -55.0 60.9 1410 1386 0.0 Ring A -50.0 60.5 1405 1381 0.1 Ring A -45.0 59.6 1395 1371 -0.1 Ring A