Loading...
HomeMy WebLinkAbout3902 Oak Shadow Way - Disclosures/Blower Door Test - 06/12/2015BUILDING LEAKAGE TEST Date of Test: 6/12/2015 Test File: 3902 Oak Shadow Wy - Ryland - MP Tectite Customer: Ryland Homes Technician: Tyler Stein - EnergyLogic Inc. Project Number: 35226 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Building Address: 3902 Oak Shadow Wy Fort Collins, CO 80528 1076 CFM50 (+/- 1.1 %) 1.79 ACH50 59.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 113.5 (+/ 20.9 %) Exponent (n) = 0.575 (+/- 0.054) Correlation Coefficient = 0.99560 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 51.0 CFM 0.08 ACH 17.0 CFM per person 2. Estimated Design Infiltration Rate: Winter: 72.1 CFM Summer: 52.9 CFM 0.12 ACH 0.09 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 60.3 CFM Base Rate: 60.3 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/12/2015 Test File: 3902 Oak Shadow Wy - Ryland - MP Tectite Building Information Location Climate Information Volume 36079 Surface Area 7580 Floor Area 3781 Height 10 # of Bedrooms 2 # of Occupants 3 Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 12830-7 3/22/2013 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/12/2015 Test File: 3902 Oak Shadow Wy - Ryland - MP Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature CF) Altitude (ft) 68.0 68.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration -4.1 n/a n/a -65.2 -61.7 43.7 1200 1216 0.2 Ring A -62.3 -58.7 39.7 1143 1159 -1.8 Ring A -58.5 -54.9 38.1 1121 1136 0.0 Ring A -54.0 -50.4 35.2 1079 1094 1.1 Ring A -50.8 -47.2 32.2 1033 1047 0.5 Ring A -45.7 -42.1 28.7 977 991 1.6 Ring A -42.1 -38.5 234.6 907 919 -0.7 Ring B -38.0 -34.4 205.2 848 860 -0.9 Ring B -3.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/12/2015 Test File: 3902 Oak Shadow Wy - Ryland - MP Tectite Comments Connections to: Garage = -45.4 Pa Mechanicals = -50