Loading...
HomeMy WebLinkAbout2403 Copper Crest Ln - Disclosures/Blower Door Test - 08/06/2014BUILDING LEAKAGE TEST Date of Test: 8/6/2014 Technician: Doug Groff Test File: Meritage Blower Door Customer: Meritage Homes 7400 E Orchard Rd Greenwood Village, Colorado 80111 Phone Building Address: 2403 Copper Crest Lane Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 1526 CFM ( +/- 0.1 %) (50 Pa = 0.2 w.c.) 1.58 ACH 0.30 CFM per ft2 floor area 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 0.14 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 1263.7 ( +/- 1.7 %) Exponent (n) = 0.048 ( +/- 0.004 ) Correlation Coefficient = 0.98904 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 546.1 CFM 0.57 ACH 2. Estimated Design Infiltration Rate: Winter: 647.4 CFM 0.67 ACH Summer: 367.8 CFM 0.38 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 8/6/2014 Test File: Meritage Blower Door Building Conditions Inside Temperature: 76 deg F Heating Fuel: Gas Outside Temperature: 60 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 57857 ft3 Ventilation Weather Factor: 0.87 Surface Area: 10560 ft2 Energy Climate Factor: 17.0 Floor Area: 5031 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage WRT Home @ 50 PA 39 and 47 BUILDING LEAKAGE TEST Page 3 Date of Test: 8/6/2014 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -0.8 n/a +/- 0.00 -65.0 75.9 1570 1546 0.1 Ring A -60.0 75.0 1560 1537 -0.1 Ring A -55.0 74.5 1555 1532 -0.0 Ring A -50.0 74.0 1550 1527 0.1 Ring A -45.0 73.0 1540 1517 -0.0 Ring A