HomeMy WebLinkAbout2232 Bar Harbor Dr - Disclosures/Blower Door Test - 05/28/2014BUILDING LEAKAGE TEST GS Services 2000 S. College Ave #308 Fort Collins, CO 80525 Date of Test: 5/28/2014 Test File: Journey Homes 2232 Bar Harbor Ln BD Technician: Paul Higman Project Number: Customer: Journey Homes Greeley, CO 80634 Building Address: 2232 Bar Harbor Ln Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1376 CFM50 ( +/- 2.1 %) (50 Pa = 0.2 w.c.) 2.70 ACH50 2. Leakage Area: 75.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 84.3 ( +/- 15.6 %) Exponent (n) = 0.714 ( +/- 0.043 ) Correlation Coefficient = 0.99771 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 77.7 CFM 0.15 ACH 2. Estimated Design Infiltration Rate: Winter: 125.3 CFM 0.25 ACH Summer: 83.2 CFM 0.16 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/28/2014 Test File: Journey Homes 2232 Bar Harbor Ln BD Building Information Volume 30621 Surface Area Floor Area 3162 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/28/2014 Test File: Journey Homes 2232 Bar Harbor Ln BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 75.0 79.0 4950.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.8 n/a n/a -60.1 -58.1 65.6 1462 1542 0.6 Ring A -55.2 -53.3 57.6 1372 1447 0.6 Ring A -50.2 -48.3 49.9 1279 1349 0.6 Ring A -45.1 -43.1 42.7 1186 1251 1.0 Ring A -41.1 -39.1 36.5 1099 1159 0.3 Ring A -35.4 -33.4 27.4 955 1007 -2.5 Ring A -30.4 -28.4 204.0 846 892 -3.0 Ring B -25.1 -23.2 158.7 747 788 -0.8 Ring B -20.4 -18.4 124.0 661 697 3.2 Ring B -2.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/28/2014 Test File: Journey Homes 2232 Bar Harbor Ln BD Comments House WRT Garage = -47.8pa