Loading...
HomeMy WebLinkAbout5046 Fossil Blvd - Special Inspections/Engineering - 05/26/2015CTL I THOMPJSQN May 26, 2015 Fort Collins Housing Authority 1715 W. Mountain Ave. Fort Collins, Colorado 80521 Attention: Mr. Chadrick Martinez Subject: Letter of Substantial Completion for Redtail Ponds Permanent Supportive Housing Shade Structure Coronado Ct and College Ave Fort Collins, Colorado CTL Project No.: FC06079.003 As requested, we provided construction observation and materials testing (COMT) services for the shade structure at the Redtail Ponds Permanent Supportive Housing project at Coronado Ct and College Ave in Fort Collins, Colorado. We have reviewed our project files to determine if there are outstanding discrepancies for our services related to this project. We were scheduled for the following number of tests or observations to date: Task Weld/Bolt Inspection Number of Tests/ Date of Testing/ Observations Observation 05/14/15 The information in our project files did not indicate any outstanding discrepancies for the items listed above that were tested and observed by CTLIThompson, Inc. To the best of our knowledge, the services described above were generally performed in substantial conformance with the project plans, specifications, and structural revisions. If we can be of further assistance, please contact us at your convenience. Very truly yours, CTL�I THOMP INC. Revip ed , Q RfriG o: Heather Grubb V1 Th04 dsR, P'E Field Department Manager BManag r 400 N. Link Lane I Fort Collins, Colorado 80524 Teleohone:970-206-9455 Fax:970-206-9441 FORT COLLINS HOUSING AUTHORITY 1715 W. MOUNTAIN AVE. FORT COLLINS CO 80521 WE ARE TRANSMITTING: FOR DATES NJ..� A.f.�lI1I: \'f\YI�Y/.�if�li.lTle-Aw n V LETTER OF TRANSMITTAL Date: FRIDAY, MAY 15, 2015 Project: REDTAIL PONDS PERMANENT SUPPORTIVE HOUSING Project No: FC06079.003 Weld and/or Bolt Inspection Results 5/14/2015 REMARKS: See attached summary reports for information. COPIES MAILED TO: CTL I Thompson, Inc WYATT KNUTSON, PE REGIONAL MANAGER `DOC vU�tis ., t� / ' o;koo 38108 z; 'AY 1 9 r`S�ONAL 400 North Link Lane I Fort Collins, CO 80524 1 Phone: 970-206-9455 1 Fax: 970-206-9441 WELD / BOLT INSPECTION REPORT SUMMARY Client Name: FORT COLLINS HOUSING AUTHORITY Inspection Date: 05/14/2015 Project: REDTAIL PONDS PERMANENT SUPPORTIVE HOUSING Project Number: FC06079.003 Report Number: 14 TYPE OF INSPECTION / APPLICABLE CODE ❑ Visual Weld AWS D1.1-02 Table 6.1 ❑ Magnetic Particle Weld AWS D1.1-02 Sect. 6.10 ❑ Liquid Dye Penetrant Weld AWS 131.1-02 Sect. 6.10 Location and Description of Work: WELDS BOLTS T_ Field Rep: JACK PAPPERT ❑ Ultrasonic Weld ❑ Decking AWS D1.1-02 Sect. 6.13 AWS D1.3-02 Sect. 4.5 O High Strength Bolt AISC Spec. for Structural Joints Using ASTM A 325 or A490 Bolts, Sect. 8 & 9. ❑ Anchor Bolts Project Specifications We inspected the bolted connections at all gridlines of the shade shelter roof framing. All of the bolts were in the snug -tight condition or greater with washers installed at the time of our inspection. Plans were prepared by K L & A, project no. 3904, dated May, 2015. At the time of our inspection, the items observed met the quality standards sited above unless noted below. ❑ Discrepancies were observed, please see the attached Outstanding Discrepancies list. Specific information is presented on the following inspection reports. 400 North Link Lane I Fort Collins, CO 80524 1 Phone: 970-206-9455 1 Fax: 970-206-9441