HomeMy WebLinkAbout538 Cajetan St - Disclosures/Blower Door Test - 11/20/2014k S N BUILDING LEAKAGE TEST Date of Test: 11/20/2014 Customer: FR Development Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) . 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates GS Services 2000 S College Ave. Suite 308 Fort Collins, CO 80525 fJ -1 A 402 6 Test File: FIR Development - 538 Cajetan - Vienna - BD1 Technician: Project Number: Building Address: 538 Cajetan Fort Collins, CO 80525 1239 CFM50 (+/- 0.8 %) 2.87 ACH50 68.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 91.4 ( +/- 5.5 %) Exponent (n) = 0.666 ( +/- 0.015 ) Correlation Coefficient = 0.99974 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 73.3 CFM 0.17 ACH 18.3 CFM per person Winter: 135.9 CFM Summer: 85.3 CFM 0.32 ACH 0.20 ACH Digganansigned by. Paul Paul :DN: CN = Paul Higman C = HigmanSf zo,a.,z.os,s:o,:ns- os�oa GSEGf?'S BUILDING LEAKAGE TEST Page 2 of 4 D no Date of Test: 11/20/2014 Test File: FIRDevelopment - 538 Cajetan - Viennai-BD1 � C,:0-6 — Building Information Location Climate Information Volume 25885 Surface Area Floor Area 2559 Height 21 # of Bedrooms 3 # of Occupants 4 Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default es BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/20/2014 Test File: FR Development - 538 Cajetan - Vienna - BD1 1-7 lv Depressurization Test: 4 UJ e Environmental -Data Indoor Temperature (AOF) Outdoor Temperature (%°F) Altitude (ft) 65.0 60.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.1 n/a n/a -60.9 -59.9 57.7 -55.2 -54.2 50.3 -48.9 -47.9 42.6 -42.6 -41.5 34.6 -36.7 -35.6 27.8 -31.1 -30.1 216.9 -24.9 -23.9 159.7 -19.0 -17.9 105.8 -1.1 n/a n/a Time Averaging Period: 0 None 1373 1399 0.1 Ring A 1284 1308 0.1 Ring A 1185 1207 0.3 Ring A 1070 1090 -0.4 Ring A 961 979 -1.0 Ring A 872 889 0.7 Ring B 749 764 0.9 Ring B 611 623 -0.5 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/20/2014 Test File: FIR Development - 538 Cajetan - Vienna - BD1 i Comments �D—i� House WRT Garage =-47.8pa [[[��� -- 2012 IECC Target is < 1294