HomeMy WebLinkAbout356 Lupine Dr - Disclosures/Blower Door Test - 03/16/2015t BUILDING LEAKAGE TEST Date of Test: 311612015 Test File: 356 Lupine Customer: Aspen Heights Technician: Greg F- Efficiency Matters Aspen Heights Project Number: Fort Collins, CO Phone: 573-286-7115 Building Address: Denver(Frisco) Email: atuttle@myaspenheights.com 356 Lupine Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 957 CFM50 3.49 ACH50 52.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 75.3 Exponent (n) = 0.650 (Assumed) Test Standard: RESNET One -Point Test Test Mode: Depressurization 5. Accuracy Level Reduced Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 43.9 CFM 0.16 ACH 2. Estimated Design Infiltration Rate: Winter: 64.2 CFM 0.23 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Summer: 47.1 CFM 0.17 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/16/2015 Test File: 356 Lupine Building Information Volume 16443 Surface Area Floor Area 1827 Height 9 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/16/2015 Test File: 356 Lupine Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 69.0 35.0 4800.0 Baseline Pressure Data Baseline 1 (Pa) 47 Baseline 2 49 Baseline 3 48 Baseline 4 52 Baseline 5 51 Average Baseline (Pa) 49.4 Baseline Range (Pa) 5.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) Configuration -50.9 285.9 1000 968 Ring B Time Averaging Period: 10 Deviations from Standard RESNET One -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/16/2015 Test File: 356 Lupine Comments None