January 26, 2015
Fort Collins Housing Authority
1715 W. Mountain Ave.
Fort Collins, Colorado 80521
S_Q �_t( rSS"I1 194VJ.
Attention: Mr. Chadrick Martinez
Subject: Letter of Substantial Completion for
Redtail Ponds Permanent Supportive Housing
Coronado Ct and College Ave
Fort Collins, Colorado
CTL Project No.: FC06079,003-345
As requested, we provided construction observation and materials testing (COMT) services
for the Redtail Ponds Permanent Supportive Housing project at Coronado Ct and College Ave in
Fort Collins, Colorado. We have reviewed our project files to determine if there are outstanding
discrepancies for our services related to this project. We were scheduled for the following number
of tests or observations to date:
Number of Tests/
Date of Testing/
Task
Observations
Observation
Soils Observation/Compaction Testing
48
03/28/14 to 12/17/1.4
Asphalt Observation/Compaction Testing
4
06/19/14 to 10/14/14
Reinforcing Steel Observation
8
04/22/1.4 to 12/10/14
Concrete Testing
29
04/23/14 to 12/11/14
Structural Masonry Observation
35
06/28/14 to 07/26/14
Masonry Materials Testing
12
06/14/14 to 07/19/14
Weld/Bolt Inspection
9
06/24/14 to 10/15/14
Sheathing Observation
4
08/28/14 to 09/29/14
Hold-down Observation
2
10/16/14 to 12/05/14
Flashing Observation
1
09/12/14
Structural Repair Observation
3
10/22/14 to 01/06/15
Our project files indicated the concrete cylinders cast on June 20, 2014 (concrete ticket no.
K114722) did not make the 28-day specified strength of 5,000 psi until 56-days and that the
concrete cylinders cast on June 20, 2014 (concrete ticket no. K114723), only made 93% of the 28-
day specified strength of 5,000 psi at 28-days and 98% at 56-days.
Our project files also indicated the mortar specimens cast on July 1, 2014 only made 96% of
the 28-day specified strength of 1,500 psi at 28-days.
In addition, we were not requested to re -inspect the outstanding discrepancies from our
weld/bolt report dated August 1, 2014; however, it is our understanding that the engineer of record
performed a re -inspection of these areas.
400 N. Link Lane i Fort Collins, Colorado 80524
Telephone:970-206-9455 Fax:970-206-9441
r
The information in our project files did not indicate any other outstanding discrepancies for
the items listed above that were tested and observed by CTLIThompson, Inc. To the best of our
knowledge, the services described above were generally performed in substantial conformance with
the project plans, specifications, and structural revisions.
If we can be of further assistance, please contact us at your convenience.
Very truly yours, 4,P� ° Ry G�Sr�
CTL I THOMPSON, INC. By:
35117
Heather Grubb yne Tho pso ,•P�
Field Department Manager Bh,llan ger�ti�C<
CITY OF FORT COLLINS
REDTAIL PONDS PERMANENT SUPPORTIVE HOUSING
CTL I T PROJECT NO. FC06079.063