HomeMy WebLinkAbout5046 Fossil Blvd - Special Inspections/Engineering - 01/26/20151 UN 111 # iloa d"s!O I'a RwAx: P '§� r.1Al ywq January 26, 2015 Fort Collins Housing Authority 1715 W. Mountain Ave. Fort Collins, Colorado 80521 S_Q �_t( rSS"I1 194VJ. Attention: Mr. Chadrick Martinez Subject: Letter of Substantial Completion for Redtail Ponds Permanent Supportive Housing Coronado Ct and College Ave Fort Collins, Colorado CTL Project No.: FC06079,003-345 As requested, we provided construction observation and materials testing (COMT) services for the Redtail Ponds Permanent Supportive Housing project at Coronado Ct and College Ave in Fort Collins, Colorado. We have reviewed our project files to determine if there are outstanding discrepancies for our services related to this project. We were scheduled for the following number of tests or observations to date: Number of Tests/ Date of Testing/ Task Observations Observation Soils Observation/Compaction Testing 48 03/28/14 to 12/17/1.4 Asphalt Observation/Compaction Testing 4 06/19/14 to 10/14/14 Reinforcing Steel Observation 8 04/22/1.4 to 12/10/14 Concrete Testing 29 04/23/14 to 12/11/14 Structural Masonry Observation 35 06/28/14 to 07/26/14 Masonry Materials Testing 12 06/14/14 to 07/19/14 Weld/Bolt Inspection 9 06/24/14 to 10/15/14 Sheathing Observation 4 08/28/14 to 09/29/14 Hold-down Observation 2 10/16/14 to 12/05/14 Flashing Observation 1 09/12/14 Structural Repair Observation 3 10/22/14 to 01/06/15 Our project files indicated the concrete cylinders cast on June 20, 2014 (concrete ticket no. K114722) did not make the 28-day specified strength of 5,000 psi until 56-days and that the concrete cylinders cast on June 20, 2014 (concrete ticket no. K114723), only made 93% of the 28- day specified strength of 5,000 psi at 28-days and 98% at 56-days. Our project files also indicated the mortar specimens cast on July 1, 2014 only made 96% of the 28-day specified strength of 1,500 psi at 28-days. In addition, we were not requested to re -inspect the outstanding discrepancies from our weld/bolt report dated August 1, 2014; however, it is our understanding that the engineer of record performed a re -inspection of these areas. 400 N. Link Lane i Fort Collins, Colorado 80524 Telephone:970-206-9455 Fax:970-206-9441 r The information in our project files did not indicate any other outstanding discrepancies for the items listed above that were tested and observed by CTLIThompson, Inc. To the best of our knowledge, the services described above were generally performed in substantial conformance with the project plans, specifications, and structural revisions. If we can be of further assistance, please contact us at your convenience. Very truly yours, 4,P� ° Ry G�Sr� CTL I THOMPSON, INC. By: 35117 Heather Grubb yne Tho pso ,•P� Field Department Manager Bh,llan ger�ti�C< CITY OF FORT COLLINS REDTAIL PONDS PERMANENT SUPPORTIVE HOUSING CTL I T PROJECT NO. FC06079.063