HomeMy WebLinkAbout517 Edwards St - Disclosures/Final Energy - 04/23/2015City of
fort Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction
SPA Guide
1. Submittal and Rating Type
U Stock Plan Permit— Projected Worst -Case Rating
U Lot -specific Permit- Projected Rating
U Completed Home —Confirmed Rating
2. Data Required for All SPA Ratings
Builder: Stratton Custom Homes
Energy Rater: Paul Higman
Builder Model:
Address:
Address: 517 Edwards
Rating Firm: GS Services
423-15
Date:
Duct Location Inputs (REM/Rate "Duct Systems" page)
Duct Location
Su ply
Return
% Area
I R-Value
% Area
R-Value
All within Conditioned space
100
r-0
100
r-0
Thermal Envelope Clarification
Component
Thermal Location
Crawl space
® NIA
❑ Inside
❑ Outside
Attic
❑ NIA
❑ Inside
® Outside
Bonus room
® NIA
❑ Inside
❑ Outside
Ductwork adjacent to garage
® N/A
❑ Inside
❑ Outside
Other:
❑ N/A
❑ Inside
❑ Outside
Utility Rates
Energy
Service
I
Variable
Source
Charge
Rate
Electricity
5 $/mo
0.1 $/kWh
Natural
15 $Imo
o.s $/therm
as
3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating
Worst -Case Configuration
Front elevation
Foundation
orientation
t e s
Options
included
U Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
U Attach REM/Rate Energy Code Inspection Checklist
313. Additional Information for Lot -Specific Permit— Projected Rating
U Attach REM/Rate 2012IECC Energy Cost Compliance report showing "PASS"
U Attach REM/Rate Energy Code Inspection Checklist
3C. Additional Information for Completed Home — Confirmed Rating
U Attach REM/Rate 20121ECC Energy Cost Compliance report showing "PASS"
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
U Attach REM/Rate Home Energy Rating Certificate
Updated 03/01/2014
�: y �►: 5;
91
Property
Stratton Custom Homes
517 Edwards
Fort Collins, CO 80524
Weather:Ft. Collins, CO
517 Edwards
Stratton 517 Edwards
Organization
GS Services Ltd
970-449-1612
Paul Higman
Builder
Stratton Custom Homes
f �
T
Annual Energy Cost $/yr
2012 IECC As Designed
Mandatory Requirements
This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 5.6%.a U I Digitally signed
P r by;=PauI H i g m a n
man Signature
DN =CN =Paul
Name Paul Hi
g g Higman Higman C = US
OGS Services Ltd Date 24 April 2015 Date: 2015.04.24
rganization
14.47:30-06'00'
Mechanical Systems
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.4.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.