Loading...
HomeMy WebLinkAbout2144 Yearling Dr - Disclosures/Blower Door Test - 04/03/2015BUILDING LEAKAGE TEST Date of Test: 4/3/2015 Test File: 2144 Yearling Dr - DR Horton - MP Tectite Customer: DR Horton Technician: Tyler Stein - EnergyLogic Inc. Project Number: 34772 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Building Address: 2144 Yearling Dr Fort Collins, CO 80525 2337 CFM50 (+/- 0.6 %) 2.76 ACH50 128.5 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 124.7 ( +/- 10.4 %) Exponent (n) = 0.749 ( +/- 0.027 ) Correlation Coefficient = 0.99935 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 153.9 CFM 0.18 ACH 25.7 CFM per person Winter: 256.3 CFM Summer: 160.8 CFM 0.30 ACH 0.19 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 72.8 CFM Base Rate: 97.4 CFM Infiltration Credit: <24.6 CFM> No Text � BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/3/2015 Test File: 2144 Yearling Dr- DR Horton- MP Tectite Depressurization Test: Environmental Data Indoor Temperature(°F) Outdoor Temperature (°F) Altitude (ft) 65.0 36.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) °/a Error Configuration -2.5 n/a n/a -64.8 -61.5 33.3 2802 2738 0.3 Open -60.5 -57.3 29.8 2657 2595 0.3 Open -56.4 -53.2 26.5 2507 2449 0.1 Open -52.7 -49.5 175.5 2362 2307 -0.5 Ring A -48.6 -45.3 154.4 2219 2168 -0.1 Ring A -45.0 -41.7 136:2 2087 2039 -0.1 Ring A -40.3 -37.0 111.3 1891. 1848 -1.0 Ririg A 36.2 -32.9 96.7 1767 1726 1.0 Ring A -4.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None " BUILDING LEAKAGE TEST Page 4 of 4 Date of Test:4/3/2015 Test File: 2144 Yearling Dr- DR Horton- MP Tectite Comments Connections to: Garage=-45.1 Pa Mechanicals=-50