Loading...
HomeMy WebLinkAbout2045 Blue Yonder Way - Special Inspections/Engineering - 08/22/2014A.G. enaar Geotechnical and Environmental Consultants D R Horton 9555 South Kingston Court, Suite 200 Englewood, Colorado 80112-5943 Attention: Mr. Tim Karns 2180 South Ivanhoe Street, Suite 5 E)enver, Colorado 80222-5710 ^ 303-759-8100 Fax 303-756-2920 www.agwassenaaccom August 22, 2014 Subject: Foundation Recommendation Verification Proposed Residential Structure Lot 20, Block 12 Sidehill, Filing 2 Fort Collins, Colorado Project Number 131341 References: 1. "Soil and Foundation Study Proposed Residential Structure Lot 20, Block 23 Sidehill, Filing 2 Fort Collins, Colorado" By A. G. Wassenaar, Inc. Project Number 131341 Dated August 23, 2013 2. "Fill Observation Sidehill, Filing 2 Fort Collins, Colorado" By A. G. Wassenaar, Inc. Project Number 143115 Dear Mr. Karns: D 33 100 a 4 12 5 / 7 As requested, an exploratory boring was drilled and laboratory testing of the fill material placed at the subject site was conducted. It is our understanding that the requirements for construction of a footing foundation to support the subject structure presented in Reference 1 were followed prior to drilling. The boring was drilled on July 23, 2014 in the approximate center of the building pad approximately 2 feet below the sidewalk. We understand the depth of the basement excavation will be about 7 feet below the sidewalk. The boring encountered the following material: 0to 15' Fill (moisture treated), clay, stiff to very stiff, sandy to very sandy, with scattered gravel, moist, brown 15' to 181/2' Sand, loose to medium dense, silty to clayey, with scattered gravel, moist to wet, brown to red brown 181/z' to 20' Sand and Gravel, dense, clean to silty, wet, brown to red brown D R Horton � Project Number 131341 �"�' � /� �^ � Il� ,r%� � � � August 22, 2014 � � �� Page 2 Ground water was encountered at a depth of approximately 17 feet at the time of drilling. The fill samples were tested for swell/consolidation upon wetting under a 1,000 pounds per square foot (psfl load. The results of the swell/consolidation tests are summarized in the table below. Percent(%) I Depth (feet) Swell (+) /Consolidation (-) 4 0.0 g -0.4 Based upon our observation and testing of the fill during placement (Reference 2) and the data presented above, it is our opinion that the fill is appropriate for foundation construction of the proposed residential structure. The recommendations presented in the"Soil and Foundation Study" (Reference 1) should be followed for the design and construction of a footing foundation. All other recommendations for a footing site should continue to be followed. If there are any questions concerning the contents of this letter, please contact our office. Sincerely, ,�>a�������RE�G��iii������ A. G. WASSENAAR oNC�.p.S��ST���/ / .,.�� ( = o. - I U: � _I n 9 . Keith D. Seaton,�. �� %�.`� � /' � Senior Engineer �O� ��\\ I �,� •,. � KDS/lia ////%s�//%IIIjINll111111\����\\\