Loading...
HomeMy WebLinkAbout3003 Bryce Dr - Disclosures/Blower Door Test - 12/05/2014G-S' Serv' es BUILDING LEAKAGE TEST GS Services 2000 S. College Ave Suite 308 Fort Co`lllps, CO 80525 % 7 DJ �2 >. Date of Test: 12/5/2014 Test File: h o homes 3003 Bryce dr BD Customer: H&O Homes Technician: Paul Higman 3926 Sunstone Way Project Number: Fort Collins, CO 80525 Building Address: 3003 Bryce Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1769 CFM50 (+/- 0.2 %) (50 Pa = 0.2 w.c.) 2.59 ACH50 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level 97.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 144.3 (+/_ 1.4 %) Exponent (n) = 0.641 ( +/- 0.004 ) Correlation Coefficient = 0.99998 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 83.8 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 118.6 CFM Summer: 87.0 CFM 0.17ACH 0.13ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: GS Services BUILDING LEAKAGE TEST Date of Test: 12/5/2014 Test File: h o homes 3003 Bryce dr BD Building Information Volume 40978 Surface Area Floor Area 4234 Height 10 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Page 2 of �4n Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory I Model 3 (110V) 1 8584 Default s- •:r i5 GS Services BUILDING LEAKAGE TEST Page [1, 4� /jq j], Date of Test: 12/512014 Test File: h o homes 3003 Bryce dr BD ���III� JI LJv 80 /-/=���� Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 65.0 54.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -0.1 n/a n/a -60.2 -59.7 120.8 -54.4 -54.0 106.5 -48.0 -47.5 90.0 42.1 -41.6 75.2 -35.9 -35.4 61.0 -29.9 -29.4 47.7 -23.9 -23.4 35.6 -17.9 -17.4 227.9 -0.9 n/a n/a Time Averaging Period: 0 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1969 1979 -0.2 Ring A 1852 1861 0.2 Ring A 1706 1714 0.2 Ring A 1562 1570 -0.1 Ring A 1410 1418 -0.1 Ring A 1252 1258 -0.0 Ring A 1085 1091 0.2 Ring A 894 898 -0.1 Ring B Deviations from Standard RESNET Multi -Point Test -Test Parameters a= '-, y, � GS Ser_vices �.�— BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12l5/2014 Test File: h o homes 3003 Bryce dr BD ��J� � �� � � �� � �� � � `_l.� k'� � `J t�,� `.�� Comments House WRT Garage=-47.6 pa