HomeMy WebLinkAbout5112 Daylight Ct - Disclosures/Blower Door Test - 04/22/2015f �
�! Ly'� 1 •-irn
lx ervwRs
Date of Test: 4/22/2015
Customer: Houts Dev and Const
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Infiltration Estimates
BUILDING LEAKAGE TEST
GS Services Ltd
2000 South College Ave
Suite 308
Fort Collins, Co 80525
Test File: Houts Dev and Const - 5112 Daylight ct - BD1
Technician: Paul Higman
Project Number:
Building Address: 5112 Daylight Ct
Fort Collins, CO 80528
1690 CFM50 (+/- 1.1 %)
2.76 ACH50
93.0 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 106.6 (+/- 9.0 %)
Exponent (n) = 0.706 ( +/- 0.025 )
Correlation Coefficient = 0.99924
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
1. Estimated Average Annual Infiltration Rate: 80.1 CFM
0.13ACH
2. Estimated Design Infiltration Rate: Winter: 113.3 CFM Summer: 83.1 CFM
0.19 ACH 0.14 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Paul Digitally signed by:
Fa (Higman
s;17, :/CN = Paul
Higmam manC=US
;Di(e: 2015.04.23 13:
f f111:40-06-00'
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 4/22/2015 Test File: Houts Dev and Const - 5112 Daylight ct - BD1
Building Information
Volume
36729
Surface Area
Floor Area
3689
Height
10
# of Bedrooms
4
# of Occupants
Year of Construction
2015
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
I Model 3 (110V)
I
I Default
R3 "c%n'h
GSy C BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 4/22/2015 Test File: Houts Dev and Const - 5112 Daylight ct - BD1
Depressurization Test:
Environmental Data
Indoor Temperature (A°F)
Outdoor Temperature (A°F)
Altitude (ft)
74.0
54.0
1 5000.0
Data Points
Nominal
Baseline Adjusted
Fan
Building Pressure
Building Pressure
Pressure
(Pa)
(Pa)
(Pa)
-2.7
n/a
n/a
-62.0
-59.4
110.8
-57.6
-54.9
99.0
-52.4
-49.8
89.3
-47.3
-44.6
75.0
-41.8
-39.2
61.9
-38.1
-35.5
54.2
-33.4
-30.8
41.7
-28.1
-25.5
33.5
-22.7
-20.1
222.0
-2.6
n/a
n/a
Time Averaging Period: 0
None
Nominal Adjusted
Flow Flow Fan
(cfm) (cfm) % Error Configuration
1887
1895
-0.7
Ring A
1787
1794
-0.7
Ring A
1699
1706
1.2
Ring A
1560
1566
0.4
Ring A
1421
1427
0.3
Ring A
1332
1338
0.9
(ling A
1172
1176
-2.0
Ring A
1053
1057
0.7
Ring A
882
886
-0.1
Ring B
Deviations from Standard RESNET Multi -Point Test - Test Parameters
5 BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 4/22/2015 Test File: Houts Dev and Const - 5112 Daylight ct - 13131
Comments
House WRT Garage =-46.Opa