Loading...
HomeMy WebLinkAbout2780 Exmoor Ln - Disclosures/Final Energy - 02/17/2015rt Collins 2 Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type ❑ Stock Plan Permit — Projected Worst -Case Rating ❑ Lot -specific Permit - Projected Rating ❑ Completed Home — Confirmed Rating 2. Data Required for All SPA Ratings Builder: Journey Homes Energy Rater: Paul Higman illel: A [`ij 4 11 Buikd M i r, E: , Address: Address: 2780 Exmoor Lane GS Services Rating Firm: 2-17-* 1 Date: 1 Duct Location Inputs (REM/Rate "Duct Systems" page) Duct Location Su ply Return % Area R-Value % Area R-Value All within Conditioned space 100 r-0 100 r-0 Thermal Envelope Clarification Component Thermal Location Crawl space ® N/A ❑ Inside ❑ Outside Attic ❑ N/A ❑ Inside ® Outside Bonus room ® N/A ❑ Inside ❑ Outside Ductwork adjacent to garage ® N/A ❑ Inside ❑ Outside Other: ❑ N/A El Inside El Outside Utility Rates Energy Service Variable Source Charge Rate Electricity 5 $/mo al $/kWh Natural 15 $/mo 0.6 $/therm as 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration Front elevation Foundation orientation type(s) Options included ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS' ❑ Attach REM/Rate Energy Code Inspection Checklist 3B. Additional Information for Lot -Specific Permit— Projected Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS' ❑ Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS' (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) ❑ Attach REM/Rate Home Energy Rating Certificate Updated 03/01/2014 Energy2012 IECC s Compliance Property Organization Journey Homes GS Services Ltd 2780 Exmoor Lane 970-449-1612 } fn ft ), � _ Fort Collins, CO 80525 Paul higman I - I /�I l I I rt l f! �t1 I� 4 Weather:Ft. Collins, CO Builder 4' 2780 Exmoor Lane Journey Homes Journey Homes 2780 Exmoor Lane Annual Energy Cost $/yr 2012 IECC As Designed Heating 264 265 Cooling 80 '651 'Water Heating " 340 3401 SubTotal - Used to Determine Compliance 684 67011 Lights E Appliances 685 686 Rhotovoltaics 0 .01 1 :Service Charge 204 ° 2041 ;Total 1573 1560'. Mandatory Requirements Window d Factor Check (Section 402.5) 1 Window U-Factor (Design must be equal orower) 0.480 0.320 Home Infiltration (Section 402.4.1.2) PASSES; Duct Leakage (Section 403.2.2) PASSES Mechanical Vehtilation (Section, 4O3.5) PASSES? This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 2.0%. Digitally signed Paul by: Paul Higman DN: CN = Paul Name Paul higman Signature H ig manHigman C = US Date: 2015.02.1 Organization GS Services Ltd Date 17 February 2015 14:52:54-06'00' Mechanical Systems Heating Fuel -fired air distribution, 40.0 kBtuh, 92.1 AFUE. Cooling Air conditioner, 24.0 kBtuh, 13.0 SEER. Water Heating Conventional, Elec, 0.95 EF. Window -to -Floor Area Ratio:, . 0.08, - I Blower door test Htg 871 Clg: 871 CFM5O In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. O 1985-2014 Architectural Energy Corporation, Boulder, Colorado.